HP StorageWorks P9000 Manual page 237

Remote web console messages
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Table 59 Error codes (part code 7005) (continued)
Part
Error
Error Message
Code
Number
7005
8558
The command has been rejected,
because the specified volume is blocked
or used as a system disk.
7005
8559
The volume is being formatted.
7005
8560
This volume cannot be specified because
it is used as a command device.
7005
8561
The command code is invalid.
7005
8562
The command code sender is invalid.
7005
8563
The volume type is invalid.
7005
8564
The volume type is invalid.
7005
8565
The command code sender is invalid.
7005
8566
The attribute of the reserved volume is
invalid.
7005
8567
The number of effective lists is invalid.
7005
8568
The emulation type is invalid.
7005
8569
The command has been rejected,
because the area of the differential table
or pair table to set pairs is insufficient.
7005
8570
The selected volume does not exist.
7005
8571
The volume is already defined as a
reserved volume.
7005
8572
The volume is already defined as a
P-VOL.
7005
8573
The volume is defined as a source
volume for Auto LUN.
7005
8574
The volume is defined as a target volume
for Auto LUN.
7005
8575
The selected volume is not a reserved
volume.
7005
8576
No reserved volume is available for use.
7005
8577
The number of reserved volumes to be
defined exceeds the maximum.
7005
8578
The P-VOL is already paired with a
backup volume. The P-VOL cannot be
paired with the target volume.
7005
8579
No volume is defined as a reserved
volume.
Recommended Action
Restore the blocked volume, then retry
the operation.
The system disk cannot be specified
as a reserved volume. Specify another
volume.
Wait until the volume is formatted, and
retry the operation.
Specify a volume that is not used as a
command device.
Please contact HP Technical Support.
Please contact HP Technical Support.
Check the contents, and retry.
Check the contents, and retry.
Please contact HP Technical Support.
Please contact HP Technical Support.
Please contact HP Technical Support.
Specify the volume of the supported
emulation type.
See the section "Planning number of
pairs" in the HP StorageWorks P9000
Business Copy User Guide for the
relation between the number of pairs that
can be created and the shared
memories.
Refresh the window, and retry the
operation.
Check the status of the volume.
Check the status of the volume.
Release the Auto LUN setting.
Release the Auto LUN setting.
Check the status of the volume.
Check the contents, and retry.
Stop the operation of the Reserve volume
setting, or delete the Reserve volume.
Check the contents, and retry.
Define the reserve volume, then retry the
operation.
Severity
Level
E
W
W
E
E
W
W
E
E
E
W
W
W
W
W
W
W
W
W
W
W
W
Part code 7005 237

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xp p9500Storageworks p9500

Table of Contents