Table 62 Error codes (part code 7105) (continued)
Part
Error
Error Message
Code
Number
7105
8539
There is insufficient shared memory to
create 4096 pairs.
7105
8540
There is sufficient shared memory to
create 4096 pairs, but initial subsystem
setup is required before creating pairs.
7105
8541
There is sufficient shared memory to
create 4096 pairs, and the initial
subsystem setup is complete.
7105
8542
Failed to complete the initial shared
memory setup.
7105
8543
The shared memory size is different.
7105
8544
16 Mbytes of shared memory is
available.
7105
8545
A power supply failure is detected.
7105
8546
The command was rejected. The PS OFF
is in progress.
7105
8547
A data transfer failure is detected (CHA).
7105
8548
A data transfer failure is detected (DKA).
7105
8549
The S-VOL is not implemented.
7105
8550
The command has been rejected,
because the specified S-VOL is blocked
or used as a system disk.
7105
8551
The S-VOL is being formatted.
7105
8552
This volume cannot be specified as an
S-VOL because it is used as a command
device.
7105
8553
The T-VOL is not implemented.
7105
8554
The command has been rejected,
because the specified T-VOL is blocked
or used as a system disk.
7105
8555
The T-VOL is being formatted.
7105
8556
This volume cannot be specified as an
T-VOL because it is used as a command
device.
7105
8557
The volume is not implemented.
Recommended Action
There is insufficient shared memory in
DKC. Please contact HP Technical
Support.
Please contact HP Technical Support.
Close the message box.
Please contact HP Technical Support.
Please contact HP Technical Support.
Check the contents, and retry.
Please contact HP Technical Support.
Retry the operation with power ON.
Please contact HP Technical Support.
Please contact HP Technical Support.
You cannot execute the operation for the
volume which is not implemented.
Restore the blocked volume, then retry
the operation.
The system disk cannot be specified
as an S-VOL. Specify another volume.
Wait until the volume is formatted, and
retry the operation.
As the S-VOL, specify a volume that is
not used as a command device.
You cannot execute the operation for the
volume which is not implemented.
Restore the blocked volume, then retry
the operation.
The system disk cannot be specified
as a T-VOL. Specify another volume.
Wait until the volume is formatted, and
retry the operation.
Release the command device, then retry
the operation.
You cannot execute the operation for the
volume which is not implemented.
Severity
Level
E
E
i
E
E
W
E
W
E
E
W
E
W
W
W
W
W
W
W