Viewing Events in the SEL
When the SEL Viewer is opened, the first page of events is loaded from the log and displayed. To
view the remaining events the user is provided with a series of buttons along the bottom of the
screen. The <Tab> key can be use to access the screen buttons.
RID
RT
TS
GID
ER
ST
SN
EDIR
ED1
ED2
ED3
MID
OEM
1
Used when displaying OEM SEL Records Type C0h-DFh
2
Used when displaying OEM SEL Records Type C0h-DFh and E0h-FFh
124
Acronym
Record ID
Record Type
Time Stamp
Generator ID
Event Message Format Revision
Sensor Type
Sensor Number
Event Dir and Event Type
Event Data 1
Event Data 2
Event Data 3
Manufacturer ID
OEM defined
Figure 44. SEL Viewer, Hex Display Mode