Summary of Contents for Intel SR1560SFHS - Server System - 0 MB RAM
Page 1
® Intel Server System SR1560SF Service Guide A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/ Products Intel Order Number D92960-004...
Page 2
Intel products are not designed, intended or authorized for use in any medical, life saving, or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur.
Page 3
® Intel Server System SR1560SF Service Guide...
Page 4
® Intel Server System SR1560SF Service Guide...
BIOS Setup screens, how to perform a BIOS update, and how to reset the password or ® CMOS. Information about the specific BIOS settings and screens is available in the Intel Server Board S5400SF Technical Product Specification. See “Server System References”...
Product Contents ® ® The Intel Server System SR1560SF ships with the Intel Server Board S5400SF. For further information, see the following documents: ® • Intel Server Board S5400SF Technical Product Specification ® • Intel Server System SR1560SF Technical Product Specification ®...
® Intel Server System SR1560SF - Product Code SR1560SFHS Contents ® Your Intel Server System SR1560SF ships with the following items: ® • Intel Server Board S5400SF, installed in the server system • One 600 W power supply, installed in the server system •...
Page 8
® viii Intel Server System SR1560SF Service Guide...
Safety Information Important Safety Instructions Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the ® Intel Server Deployment Toolkit 2.0 CD and/or at http://support.intel.com/support/motherboards/server/sb/cs-010770.htm.
Page 10
重要安全指导 在执行任何指令之前,请阅读本文档中的所有注意事项及安全声明。 和/或 http://support.intel.com/support/motherboards/server/sb/CS-010770.htm 上的 Intel Server Boards and Server Chassis Safety Information(《Intel 服务器主板与服务器机箱安全信息》)。 ® Intel Server System SR1560SF Service Guide...
Page 11
Take care to grip with, but not squeeze, the pliers or other tool you use to remove a jumper, or you may bend or break the pins on the board. ® Intel Server System SR1560SF Service Guide...
Page 12
® Intel Server System SR1560SF Service Guide...
Preface ......................... v About this Manual ........................v Manual Organization ......................v Product Contents ........................vi ® Intel Server System SR1560SF - Product Code SR1560SF Contents ...... vi ® Intel Server System SR1560SF - Product Code SR1560SFHS Contents ....vii Safety Information .....................
Page 14
Installing and Removing the I/O Expansion Module(s) ............41 Installing the I/O Expansion Module(s) ............... 41 Removing the I/O Expansion Module(s) ..............41 ® ® Installing and Removing the Intel Remote Management Module 2 and the Intel RMM 2 NIC ® ® Installing the Intel RMM2 and Intel RMM2 NIC ............
Page 15
Appendix A: Technical Reference ................65 600W Single Power Supply Input Voltages .................65 System Environmental Specifications ..................65 ® Appendix B: Intel Server Issue Report Form ............67 Appendix C: LED Decoder ..................71 Appendix D: Getting Help ..................77 World Wide Web ........................77 Telephone ..........................77...
Page 16
Appendix F: Warranty ....................93 Limited Warranty for Intel® Chassis Subassembly Products ..........93 Appendix G: Installation/Assembly Safety Instructions ........97 English ..........................97 Deutsch ..........................99 Français ..........................101 Español ..........................103 Chinese ..........................106 Italiano ..........................106 Appendix H: Safety Information ................109 English ..........................
Page 17
Advertencias de alimentacién y eléctricas ..............127 Advertencias sobre el cable de alimentación ............127 Advertencias el acceso al sistema ................128 Advertencias sobre el montaje en bastidor ...............129 Descarga electrostática (ESD) ..................130 Otros riesgos ......................130 ® Intel Server System SR1560SF Service Guide xvii...
Page 18
® xviii Intel Server System SR1560SF Service Guide...
Page 19
List of Figures ® Figure 1. Intel Server System SR1560SF ................3 Figure 2. Cable Routing for Hot-Swap Drive System ..............6 Figure 3. Cable Routing for Fixed Drive System ............... 7 Figure 4. System Components....................8 Figure 5. Server Board Connector and Component Locations ..........9 Figure 6.
Page 20
Figure 44. Installing the I/O Expansion Module to the Server Board ........41 Figure 45. Removing the I/O Expansion Module(s) from the Server Board......41 ® ® Figure 46. Installing the Intel RMM2 and the Intel RMM2 NIC Module to the Server System . ®...
Page 21
List of Tables Table 1. Server System References ..................1 ® Table 2. Intel Server System SR1560SF Feature Summary ........... 4 Table 3. NIC LED Descriptions ....................13 Table 4. Setup Menu Key Use ....................60 Table 5. System Environmental Specifications ...............65 Table 6.
Page 22
® xxii Intel Server System SR1560SF Service Guide...
Integrated Server System SR1560SF Quick Start User's product and need to Guide install it ® Found: in the product box and available on the Intel Server Deployment Toolkit 2.0 CD. Accessories or other Intel Spares and Configuration Guide server products Found: available from your Intel field representative or on the Server Configurator Tool at http://indigo.intel.com/...
Page 24
® For software to manage Intel System Management Software ® your Intel server ® Found: available on the Intel System Management Software CD that ships with your system. For diagnostics test Diagnostics: Platform Confidence Test (PCT) software Found at: http://support.intel.com/support/motherboards/server/S5400SF/ ®...
This chapter briefly describes the main features of the server system. This chapter provides illustrations of the product, a list of the server system features, and diagrams showing the location of important components and connections on the server system. AF002374 ® Figure 1. Intel Server System SR1560SF...
31 pounds (14.1 kg) - max chassis weight ® Server Board Intel Server Board S5400SF ® ® Processor Support for up to two Multi-Core Intel Xeon processors 5000 sequence. For a complete list of supported processors, see: http://support.intel.com/support/motherboards/server/ s5400sf/compat.htm Memory Sixteen DIMM slots •...
Page 27
® Table 2. Intel Server System SR1560SF Feature Summary Feature Description ® Intel 82563EB dual port controller for 10/100/1000 Mbit/sec Ethernet LAN connectivity • Expansion Capabilities One PCI Express* x16 GEN2 add-in card slot • Hard Drive Options Fixed drive system: –...
Use caution to make sure no cables or wires are pinched and that the airflow from the fans is not blocked. Use the figures below to determine the correct cable routing for a hot-swap drive system. Intel ® Remote Management Power to Server Board (Aux.
Use the figures below to determine the correct cable routing for a fixed drive system. Power to Fan Board (P3) Intel ® Remote Management Fan Power Cables...
(drives not included) PCI card bracket (full height) Slimline Optical Drive Bay (drive not included) PCI add-in riser assembly M. Front bezel (optional) Processor air duct Figure 4. System Components ® Intel Server System SR1560SF Service Guide...
If pins 1-2 are jumpered, the BIOS in the lower bank will be selected on the next reset. These pins should be jumpered on 2-3 for normal operation. Figure 6. BIOS Select Jumper ® Intel Server System SR1560SF Service Guide...
BMC Force Update Mode If pins 2-3 are jumpered, BMC Force Update Mode is enabled. These pins should be jumpered on 1-2 for normal operation. Figure 7. Recovery Jumpers ® Intel Server System SR1560SF Service Guide...
® Intel Light Guided Diagnostics The server board contains numerous LEDs providing the following functions: • Fault LEDs help identify failed and failing components. The fault LEDs turn on (amber) if there is a memory or processor fault. • The System Status LED that shows the over all health of the system (green, blinking green, blinking amber, amber).
No network connection Solid Amber Network connection in place Blinking Amber Transmit/receive activity Right 10 Mbps connection (if left LED is on or blinking) Solid Amber 100 Mbps connection Solid Green 1000 Mbps connection ® Intel Server System SR1560SF Service Guide...
Fan 1 power SAS/SATA1 (passive backplane only) Thumbscrew SAS/SATA2 (passive backplane only) M. Control panel data Fan 5 power Control panel USB Bridge board connector HDD connectors Fan 4 power Figure 10. Active/Passive Backplane Components ® Intel Server System SR1560SF Service Guide...
The Intel Server System SR1560SF (product code SR1560SF) provides an embedded ® SATA controller that supports both 1.5 and 3.0 Gbps data transfer rates. The Intel Server System SR1560SF (product code SR1560SFHS) provides SAS and SATA support. Both systems can be configured for RAID 0, 1, and 10.
For instructions on installing the front bezel, see “Installing the Front Bezel”. The order number for the bezel is: • ADWBEZBLACK: Black bezel for use with the standard control panel. ® Intel Server System SR1560SF Service Guide...
AC Power Receptacle NIC 2 connector Management Network Interface (optional) NIC 1 connector IO module external connector (optional) RJ45 serial B port USB 6 connector PS2 keyboard connector Figure 12. Server System Back ® Intel Server System SR1560SF Service Guide...
To use the bay for a floppy drive, the AXXFLOPHDDTRAY accessory kit must be used. ® Note: The USB floppy drive kit is supported on the Intel Server System SR1560SF - (product code SR1560SFHS) only. For instructions on installing hard drives, see “Installing and Removing a Fixed Hard...
Server System SR1560SF can be mounted into a rack. Intel provides three options to mount this server into a rack. When installing the chassis into a rack, Intel recommends you install systems from the bottom of the rack to the top. In other words, install the first system in the rack into the bottom position of the rack, the second system in the second position from the bottom, and so on.
Page 42
® Intel Server System SR1560SF Service Guide...
All references to left, right, front, top, and bottom assume the reader is facing the front of the server system as it would be positioned for normal operation. Removing and Installing the Front Bezel ® The front bezel is available as an optional accessory for the Intel Server System SR1560SF. Bezel product code: ADWBEZBLACK.
The server system must be operated with the system cover in place to ensure proper cooling. You will need to remove the top cover to add or replace components inside of the server. ® Intel Server System SR1560SF Service Guide...
1. Slide the cover forward until it clicks into place (see letter “A”). 2. Insert the screw at the center of the top cover (see letter “B”). AF002370 Figure 17. Installing the Server System Cover ® Intel Server System SR1560SF Service Guide...
Notes: Do not remove the air dam if only one processor is installed. AF002366 Figure 19. Removing the Processor 2 Air Dam (Optional - only if two processors are installed) ® Intel Server System SR1560SF Service Guide...
DIMMs. Figure 21 shows the supported DIMM configuration that is recommended because it allows both memory branches from the MCH to operate independently and simultaneously. ® Intel Server System SR1560SF Service Guide...
Thermal requirement note: If x4 FBDIMMs are used, and the FBDIMMs do not have thermal sensors, you must install DIMM Blanks when installing less than 8 FBDIMMs. DIMM Blanks can be ordered through your preferred distributor. ® Intel Server System SR1560SF Service Guide...
(1) Touch the metal chassis before touching the processor or server board. Keep part of your body in contact with the metal chassis to dissipate the static charge while handling the processor. (2) Avoid moving around unnecessarily. ® Intel Server System SR1560SF Service Guide...
Figure 23. Lifting the Processor Socket Handle 2. Raise the CPU load plate (see Figure 24). TP02075 Figure 24. Installing the Processor Note: Do not touch the socket pins; they are very sensitive and easily damaged. ® Intel Server System SR1560SF Service Guide...
1. Set the heat sink over the processor, lining up the four captive screws with the four posts surrounding the processor. 2. Loosely screw in the captive screws on the heat sink corners in a diagonal manner. Do no fully tighten one screw before tightening another. ® Intel Server System SR1560SF Service Guide...
The steps below describe how to remove and then install the small air baffle. Use these steps only when it is necessary for a component installation process. ® Intel Server System SR1560SF Service Guide...
Installing the Small Air Baffle Lower the baffle into the server system and position baffle over the two stand-off locations. Press into place as shown in the figure below. AF002365 Figure 28. Installing the Small Air Baffle ® Intel Server System SR1560SF Service Guide...
Installing and Removing a Hot-swap Hard Drive ® Up to three hot-swap SAS or SATA drives can be installed in the Intel Server System SR1560SF - product code SR1560SFHS. Cautions: If you install less than three drives or devices, the empty drive bays must be occupied by carriers with drive blanks to maintain proper system cooling.
2. Remove the four screws that attach the hard drive to the drive carrier. Lift the drive from the carrier and store the drive in an anti-static bag. ® Intel Server System SR1560SF Service Guide...
AC power cord from the system or wall outlet. ® Up to two fixed SATA drives can be installed in the Intel Server System SR1560SF - product code SR1560SF.
3. Remove the four screws that attach the hard drive to the carrier. Remove the drive from the carrier and store the drive in an anti-static bag. AF002382 Figure 35. Removing Fixed Hard Drive from the Server System ® Intel Server System SR1560SF Service Guide...
5. Slide the optical drive into interposer board (see letter “B”) and lower the opposite side of the optical drive into the tray (see letter “C”). TP02210 Figure 36. Installing an Optical Drive into the Drive Tray ® Intel Server System SR1560SF Service Guide...
1. Press the blue release lever (see letter “A”) to unlock the optical drive tray and remove the slimline optical drive tray assembly from the server system (see letter “B”). AF000384 Figure 38. Removing the Slimline Optical Drive Assembly from the Server System ® Intel Server System SR1560SF Service Guide...
Installing and Removing the PCI Riser Assembly Removing the PCI Riser Assembly 1. Disconnect any cables attached to any add-in cards. 2. Grasp the riser assembly and pull up to release it from the system. ® Intel Server System SR1560SF Service Guide...
3. Press down uniformly until the two hooks on the rear of the PCI riser assembly engage the server system back panel slots. The riser card will seat into the matching socket on the server board. Ensure that the riser card is fully seated. ® Intel Server System SR1560SF Service Guide...
2. Remove the PCI add-in card from the riser card connector (see letter “B”). AF002368 Figure 43. Removing a Full Height Add-In Card Note: Make sure that all empty add-in card slots have filler panels installed. ® Intel Server System SR1560SF Service Guide...
3. Install the I/O expansion module cover into the system back panel (see letter “C”). I/O Expansion Module (Dual Gigabit) I/O Expansion Module (External SAS) AF002377 Figure 45. Removing the I/O Expansion Module(s) from the Server Board ® Intel Server System SR1560SF Service Guide...
® 4. Insert the standoff into the hole labeled TH4 on the Intel RMM2 board (see letter ® “D” in the figure below). The standoff installs on the bottom side of the Intel RMM2 board. ® 5. Attach the Intel RMM2 board to the server board connector and snap the standoff into the matching hole on the server board (see letter “E”...
3. Install the Intel RMM2 NIC module cover into the system back panel. AF002379 ® ® Figure 47. Removing the Intel RMM and the Intel RMM NIC Module from the Server System Installing/Replacing the Backplane Board (Hot- swap Drive System Only) The instructions below describe how to install and replace the backplane board.
(see letter “B”). Close the retention mechanism to hold the bridge board in place. AF000372 Figure 49. Installing the Bridge Board into the Server System ® Intel Server System SR1560SF Service Guide...
5. Hold the backplane board only by the edges. Slide the backplane board to the right to release it and lift it over the retention pins (see letter “C”). 6. Lift the backplane board out of the server system (see letter “D”). AF002349 ® Intel Server System SR1560SF Service Guide...
5. Lift the fan board out of the server system (see letter “D”). AF002351 Figure 52. Removing the Fan Board from the Server System 6. Install a replacement fan board. For instructions, see “Installing the Fan Board”. ® Intel Server System SR1560SF Service Guide...
2. If installed, remove memory, processor heat sinks, and processors from the server board. 3. If installed, remove bridge board (hot-swap systems only). 4. If installed, remove the PCI riser assembly. 5. If installed, disconnect all SATA cables from the server board. ® Intel Server System SR1560SF Service Guide...
8. Remove the seven screws from the server board (see letter “A”) and lift the server board from the server system (see letter “B”). AF002346 Figure 54. Removing the Server Board 9. Install the replacement server board. For instructions, see “Installing the Server Board”. ® Intel Server System SR1560SF Service Guide...
5. Re-connect all SATA cables to the server board. 6. Install the PCI riser assembly. 7. Install the bridge board (hot-swap systems only). 8. Install memory, processor heat sinks, and processors. 9. Install the CPU air duct and blue air baffle. ® Intel Server System SR1560SF Service Guide...
Varning: Explosionsfara vid felaktigt batteribyte. Använd samma batterityp eller en ekvivalent typ som rekommenderas av apparattillverkaren. Kassera använt batteri enligt fabrikantens instruktion. Varoitus: Paristo voi räjähtää, jos se on virheellisesti asennettu. Vaihda paristo ainoastaan laitevalmistajan suosittelemaan tyyppiin. Hävitä käytetty paristo valmistajan ohjeiden mukaisesti. ® Intel Server System SR1560SF Service Guide...
5. Connect the USB and front panel cables to the connectors on the backplane (see letters “B” and “C”). AF002343 Figure 60. Installing Control Panel Module into the Server System (Hot-swap Drive System) ® Intel Server System SR1560SF Service Guide...
4. Press the latch at the back of the control panel (see letter “D”). 5. Slide the control panel out through the front of the server system (see letter “E”). AF002344 Figure 61. Removing the Control Panel Module (Fixed Drive System) ® Intel Server System SR1560SF Service Guide...
® The system fans at the front of the Intel Server System SR1560SF can be individually replaced if one of them fails. Use the steps below to replace a fan.
3. With the fan oriented correctly, insert the fan into the fan module (see letter “A”), and insert the fan cable into the matching connector on the backplane or fan board (see letter “B”). AF002357 Figure 64. Installing a Fan into the Fan Module ® Intel Server System SR1560SF Service Guide...
Figure 65. Installing the Rack Handle Removing the Rack Handles Remove the two screws holding the rack handle in place, and remove the rack handle from the server system. AF000378 Figure 66. Removing the Rack Handle ® Intel Server System SR1560SF Service Guide...
Page 80
® Intel Server System SR1560SF Service Guide...
You can run BIOS Setup with or without an operating system ® being present. See “Server System References” for a link to the Intel Server Board S5400SF Technical Product Specification where you will find details about specific BIOS setup screens.
If "No" is selected and the <Enter> key is pressed, or if the <Esc> key is pressed, the user is returned to where they were before <F9> was pressed without affecting any existing field values. ® Intel Server System SR1560SF Service Guide...
Press <F2> Key if you want to run SETUP 2. Write down the current settings in the BIOS Setup program. Note: Do not skip step 2. You will need these settings to configure your server at the end of the procedure. ® Intel Server System SR1560SF Service Guide...
3. Move the jumper from the normal operation position, CMOS Protect at pins 1 and 2, to the CMOS Clear Force Erase position, covering pins 2 and 3. BMC Force Update Mode Disable Password Enable Reset CMOS Clear AF002170 Figure 67. Clear CMOS Jumper ® Intel Server System SR1560SF Service Guide...
5. Return the Password Reset jumper to the Password Clear Protect position, covering pins 1 and 2. 6. Close the server system. 7. Power up the server. 8. The password is now cleared and can be reset by going into BIOS setup. ® Intel Server System SR1560SF Service Guide...
Page 86
® Intel Server System SR1560SF Service Guide...
Sound Pressure: 55 dBA (rack mount) in an idle state at typical office ambient temperature. (23 +/- degrees C) Sound Power: 7.0 BA in an idle state at typical office ambient temperature. (23 +/- 2 degrees C). Electrostatic +/-15kV except I/O port +/-8KV, per Intel Environmental Test Specification. discharge (ESD)
Page 88
® Intel Server System SR1560SF Service Guide...
Appendix B: Intel Server Issue Report Form Note: An on-line / automatic submission version of this form is available at http:// support.intel.com/support/motherboards/server/s5400sf/. For the fastest service, please submit your form via the Internet. Date Submitted: _______________________________________________________ Company Name: ______________________________________________________ Contact Name: ________________________________________________________...
DIMM D2 MB and Vendor / part number: __________________________________ DIMM D3 MB and Vendor / part number: __________________________________ DIMM D4 MB and Vendor / part number: __________________________________ Operating System Information Operating System:_____________________________________________________ Version: _____________________________________________________________ Service Pack:_________________________________________________________ ® Intel Server System SR1560SF Service Guide...
Page 91
On-board Video Add-in Video On-Board NIC1 On-Board NIC2 Hard Drive Information Drive Type (SATA/ Hot-swap Make/Model SAS) or Fixed Revision Management Information On-Board Platform Instrumentation only ___________________________________ ® Intel Remote Management Module _______________________________________ ® Intel Server System SR1560SF Service Guide...
Page 92
Please also include any details on troubleshooting already done. ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ® Intel Server System SR1560SF Service Guide...
Appendix C: LED Decoder During the system boot process, BIOS executes a number of platform configuration processes, each of which is assigned a specific hex POST code number. As each configuration routine is started, BIOS will display the given POST code to the POST Code Diagnostic LEDs found on the back edge of the server board.
Detecting presence of memory 0x24h Programming timing parameters in the memory controller 0x25h Configuring memory parameters in the memory controller 0x26h Optimizing memory controller settings 0x27h Initializing memory, such as ECC init 0x28h Testing memory ® Intel Server System SR1560SF Service Guide...
Page 95
0x79h Disabling the console controller 0x7Ah Enabling the console controller Keyboard (PS2 or USB) 0x90h Resetting the keyboard 0x91h Disabling the keyboard 0x92h Detecting the presence of the keyboard 0x93h Enabling the keyboard ® Intel Server System SR1560SF Service Guide...
Page 97
0xFAh Operating system has requested the system to reset (ResetSystem () has been called) Pre-EFI Initialization Module (PEIM) / Recovery 0x30h Crisis recovery has been initiated because of a user request ® Intel Server System SR1560SF Service Guide...
Page 98
Table 7. Diagnostic LED POST Code Decoder 0x31h Crisis recovery has been initiated by software (corrupt flash) 0x34h Loading crisis recovery capsule 0x35h Handing off control to the crisis recovery capsule 0x3Fh Unable to complete crisis recovery. ® Intel Server System SR1560SF Service Guide...
Telephone All calls are billed per incident, levied in local currency at the applicable credit card exchange rate plus applicable taxes. (Intel reserves the right to change the pricing for telephone support at any time without notice). ® Before calling, fill out an “Intel...
Easter Island....Contact AT&T USA at 800 800 311. Once connected, dial 800 843 4481 Mainland and Juan .. Contact AT&T USA at 800 225 288. Once connected, dial 800 843 4481 ® Intel Server System SR1560SF Service Guide...
Page 101
Panama..Contact AT&T USA at 00 800 001 0109. Once connected, dial 800 843 4481 Paraguay ... 001 916 377 0114 Peru ... 001 916 377 0114 Uruguay..001 916 377 0114 Venezuela... Contact AT&T USA at 0 800 2255 288. Once connected, dial 800 843 4481 ® Intel Server System SR1560SF Service Guide...
Page 102
® Intel Server System SR1560SF Service Guide...
(or higher) and operating at the same (or higher) speed as the microprocessor used on this server board. The final configuration of your end system product may require additional EMC compliance testing. For more information, please contact your local Intel representative.
Belarus None Required Certification Canada / USA CSA 60950 - UL 60950 (Safety) Canada / USA Industry Canada CANADA ICES-003 CLASS A ICES-003 CANADA NMB-003 CLASSE A (Emissions) CFR 47, Part 15 (Emissions) ® Intel Server System SR1560SF Service Guide...
Page 105
CE Declaration of Conformity Germany GS Certification - EN60950 International CB Certification - None Required IEC60950 CISPR 22 / CISPR 24 Japan VCCI Certification Korea RRL Certification MIC Notice No. 1997-41 (EMC) & 1997-42 (EMI) ® Intel Server System SR1560SF Service Guide...
Page 106
Table 8. Product Regulatory Compliance Markings Compliance Regional Compliance Compliance Reference Marking Example Description Reference Russia GOST-R Certification GOST R 29216- 91 (Emissions) GOST R 50628- 95 (Immunity) Ukraine Ukraine None Required Certification Taiwan BSMI CNS13438 R33025 ® Intel Server System SR1560SF Service Guide...
(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. For questions related to the EMC performance of this product, contact: Intel Corporation 5200 N.E. Elam Young Parkway Hillsboro, OR 97124-6497 1-800-628-8686 This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
Install and use the equipment according to the instruction manual. BSMI (Taiwan) The BSMI Certification Marking and EMC warning is located on the outside rear area of the product. ® Intel Server System SR1560SF Service Guide...
5. Manufacturer/Nation: Intel Corporation/Refer to country of origin marked on product Product Ecology Compliance Intel has a system in place to restrict the use of banned substances in accordance with world wide product ecology regulatory requirements. The following is Intel's product ecology compliance criteria.
Intel Internal All materials, parts and subassemblies None Required Specification must not contain restricted materials as defined in Intel's Environmental Product Content Specification of Suppliers and Outsourced Manufacturers - http:// supplier.intel.com/ehs/environmental.htm Europe Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/ EC - Mark applied to system level products only.
Page 111
Boxed Boards Intel Internal All materials, parts and subassemblies None Required must not contain restricted materials as Specification defined in Intel's Environmental Product Content Specification of Suppliers and Outsourced Manufacturers - http:// supplier.intel.com/ehs/environmental.htm. International ISO11469 - Plastic parts weighing >25gm >PC/ABS<...
为避免遭受电击, 在进行维修之前应断开两(2) 条电源系统电缆 Traditional Chinese 注意: 本設備包括多條電源系統電纜。 遭受電擊, 在進行維修之前應斷開兩(2) 條電源系統電纜 German: Dieses Geräte hat mehr als ein Stromkabel. Um eine Gefahr des elektrischen Schlages zu verringern trennen sie beide (2) Stromkabeln bevor Instandhaltung ® Intel Server System SR1560SF Service Guide...
Updated product information for configurations can be found on the Intel Server Builder Web site at the following URL: http://channel.intel.com/go/serverbuilder If you do not have access to Intel's Web address, please contact your local Intel representative. •...
End-of-Life / Product Recycling Product recycling and end-of-life take-back systems and requirements vary by country. Contact the retailer or distributor of this product for information about product recycling and / or take-back. ® Intel Server System SR1560SF Service Guide...
"as is" unless specifically provided for otherwise in any software license accompanying the software. If any Product furnished by Intel which is the subject of this Limited Warranty fails during the warranty period for reasons covered by this Limited Warranty, Intel, at its option, will: •...
Limitations of Liability Intel's responsibility under this, or any other warranty, implied or expressed, is limited to repair, replacement, or refund, as set forth above. These remedies are the sole and exclusive remedies for any breach of warranty.
Telephone Support If you cannot find the information you need on Intel's World Wide Web site (http:// www.intel.com/), call your local distributor or an Intel Customer Support representative.
Page 118
® Intel Server System SR1560SF Service Guide...
5. Provide some electrostatic discharge (ESD) protection by wearing an antistatic wrist strap attached to chassis ground of the system-any unpainted metal surface-when handling components. 6. Do not operate the system with the chassis covers removed. ® Intel Server System SR1560SF Service Guide...
Page 120
• Provided with a properly grounded wall outlet. • Provided with sufficient space to access the power supply cord(s), because they serve as the product's main power disconnect. ® Intel Server System SR1560SF Service Guide...
Anschlußkabel von den I/O Anschlüssen oder Ports ab. 5. Tragen Sie ein geerdetes Antistatik Gelenkband, um elektrostatische Ladungen (ESD) über blanke Metallstellen bei der Handhabung der Komponenten zu vermeiden. 6. Schalten Sie das System niemals ohne ordnungsgemäß montiertes Gehäuse ein. ® Intel Server System SR1560SF Service Guide...
Page 122
Schutzhandschuhe tragen. Bei falschem Einsetzen einer neuen Batterie besteht Explosionsgefahr. Die Batterie darf nur durch denselben oder einen entsprechenden, vom Hersteller empfohlenen Batterietyp ersetzt werden. Entsorgen Sie verbrauchte Batterien den Anweisungen des Herstellers entsprechend. ® Intel Server System SR1560SF Service Guide...
Notez que le commutateur CC de mise sous tension /hors tension du panneau avant n'éteint pas l'alimentation CA du système. Pour mettre le système hors tension, vous devez débrancher chaque câble d'alimentation de sa prise. ® Intel Server System SR1560SF Service Guide...
Page 124
Le microprocesseur et le dissipateur de chaleur peuvent être chauds si le système a été sous tension. Faites également attention aux broches aiguës des cartes et aux bords tranchants du capot. Nous vous recommandons l'usage de gants de protection. ® Intel Server System SR1560SF Service Guide...
No intente modificar ni usar el cable de alimentación de corriente alterna, si no corresponde exactamente con el tipo requerido. El número de cables suministrados se corresponden con el número de fuentes de alimentación de corriente alterna que tenga el producto ® Intel Server System SR1560SF Service Guide...
Page 126
4. Inserte el bloqueo de seguridad en el sistema y bloquéelo para impedir que pueda accederse al mismo sin autorización. 5. Conecte todos los cables externos y los cables de alimentación CA al sistema. ® Intel Server System SR1560SF Service Guide...
Page 127
• "Provisto de una toma de tierra correctamente instalada. • "Provisto de espacio suficiente como para acceder a los cables de alimentación, ya que éstos hacen de medio principal de desconexión del sistema. ® Intel Server System SR1560SF Service Guide...
(SES), portando un cinghia anti-statica da polso che è attaccata alla presa a terra del telaio del sistema - qualsiasi superficie non dipinta - . 6. Non far operare il sistema quando il telaio è senza le coperture. ® Intel Server System SR1560SF Service Guide...
Page 129
• "Dotata di una presa a muro correttamente installata. • "Dotata di spazio sufficiente ad accedere ai cavi di alimentazione, i quali rappresentano il mezzo principale di scollegamento del sistema. ® Intel Server System SR1560SF Service Guide...
Page 130
® Intel Server System SR1560SF Service Guide...
To reduce the risk of bodily injury, electrical shock, fire, and equipment damage, read this document and observe all warnings and precautions in ® this guide before installing or maintaining your Intel Server Product. In the event of a conflict between the information in this document and information provided with the product or on the website for a particular product, the product documentation takes precedence.
Conform to local occupational health and safety requirements when moving and lifting equipment. • Use mechanical assistance or other suitable assistance when moving and lifting equipment. • To reduce the weight for easier handling, remove any easily detachable components. ® Intel Server System SR1560SF Service Guide...
Do not attempt to modify or use an AC power cord if it is not the exact type required. A separate AC cord is required for each system power supply. ® Some power supplies in Intel servers use Neutral Pole Fusing. To avoid risk of shock use caution when working with power supplies that use Neutral Pole Fusing.
To avoid risk of potential electric shock, a proper safety ground must be implemented for the rack and each piece of equipment installed in it. ® Intel Server System SR1560SF Service Guide...
Caution: To avoid risk of radiation exposure and/or personal injury: • Do not open the enclosure of any laser peripheral or device • Laser peripherals or devices have are not user serviceable • Return to manufacturer for servicing ® Intel Server System SR1560SF Service Guide...
Deutsch Sicherheitshinweise für den Server ® ® Das vorliegende Dokument bezieht sich auf Intel Serverplatinen, Intel Servergehäuse (Standfuß und Rack) sowie installierte Peripheriegeräte. Es enthält Warnungen und Vorsichtsmaßnahmen zur Vermeidung von Gefahren durch Verletzung, Stromschlag, Feuer und Beschädigungen von Geräten. Lesen Sie diese Dokument daher sorgfältig, ®...
Verwenden Sie mechanische oder andere geeignete Hilfsmittel zum Transportieren oder Anheben von Geräten. • Entfernen Sie alle Komponenten, die sich leicht abnehmen lassen, um das Gewicht zu reduzieren und die Handhabung zu erleichtern. ® Intel Server System SR1560SF Service Guide...
Typ entspricht. Jedes Netzteil im System muß über ein eigenes Netzkabel angeschlossen werden. Einige Netzteile von Intel Servern verwenden Nullleitersicherungen. Vorsicht ist geboten im Umgang mit Netzteilen, welche Nullleitersicherungen verwenden, um das Risiko eines elektrischen Schlages zu vermeiden Das Netzteil in diesem Produkt enthält keine Teile, die vom Benutzer gewartet werden...
Gehen Sie bei der Installation von Geräten im Rack immer von unten nach oben vor, und bauen Sie das schwerste Gerät an der untersten Position im Rack ein. Ziehen Sie jeweils immer nur ein Gerät aus dem Rack heraus. ® Intel Server System SR1560SF Service Guide...
Inbetriebnahme des Systems ohne Abdeckung kann zur Beschädigung von Systemkomponenten führen. So bringen Sie die Abdeckung wieder an: • Vergewissern Sie sich zunächst, daß Sie keine Werkzeuge oder Teile im Gehäuse vergessen haben. ® Intel Server System SR1560SF Service Guide...
® d’installer ou de mettre à jour votre produit serveur Intel En cas de conflit entre les informations fournies dans ce document et celles livrées avec le produit ou publiées sur le site Web pour un produit particulier, la documentation du produit prime.
Bien ventilé et à l’écart des sources de chaleur telles que la lumière directe du soleil et les radiateurs. • À l’écart des sources de vibration ou des chocs physiques. • Isolé des champs électromagnétiques importants produits par des appareils électriques. ® Intel Server System SR1560SF Service Guide...
Vous devez les débrancher avant d’ouvrir le châssis, d’ajouter ou de supprimer un composant non connectable à chaud. Les alimentations de certains serveurs Intel sont munies de doubles fusibles pôle/neutre: veuillez observer les précautions d'usage afin d'éviter tout risque d'eléctrocution.
Éteignez le système en appuyant sur le bouton d’alimentation. • Déconnectez l’alimentation secteur en débranchant tous les cordons d’alimentation secteur du système ou de la prise murale. • Déconnectez l’ensemble des câbles et lignes de télécommunication qui sont connectés au système. ® Intel Server System SR1560SF Service Guide...
étiqueté comme contrôlant toute l’unité, et pas uniquement le ou les serveurs. Pour éviter tout risque d’électrocution, le rack et chaque élément de l’équipement installé dans le rack doivent être correctement reliés à la terre. ® Intel Server System SR1560SF Service Guide...
Vérifiez tout d’abord que vous n’avez pas oublié d’outils ou de composants détachés à l’intérieur du système. • Vérifiez que les câbles, les cartes d’extension et les autres composants sont correctement installés. • Fixez les panneaux au châssis en suivant les instructions du produit. ® Intel Server System SR1560SF Service Guide...
Español Información de seguridad del servidor Este documento se aplica a las tarjetas de servidor de Intel®, las carcasas de servidor de Intel® (montaje en bastidor y en pedestal) y los dispositivos periféricos. Para reducir el riesgo de daños corporales, descargas eléctricas, fuego y en el equipo, lea este documento y preste atención a todos las advertencias y precauciones de esta guía antes de instalar o...
Provista de una toma de corriente alterna correctamente conectada a tierra. • Provista de espacio suficiente para acceder a los cables de la fuente de alimentación ya que constituyen la desconexión principal de la alimentación. ® Intel Server System SR1560SF Service Guide...
CA estén desenchufado antes de abrir la carcasa, agregar o extraer cualquier componente que no es de conexión en funcionamiento. Algunas fuentes de alimentación de electricidad de los servidores de Intel utilizan el polo neutral del fuselaje. Para evitar riesgos de choques electricos use precauciónes al trabajar con las fuentes de alimentación que utilizan el polo neutral de fuselaje.
Devuélvala al fabricante para repararla. • Apague el servidor y desconecte todos los cables de alimentación antes de agregar o reemplazar cualquier componente que no es de conexión en funcionamiento. ® Intel Server System SR1560SF Service Guide...
Para evitar el riesgo de descargas eléctricas, deberá instalar una conexión a tierra apropiada para el bastidor y para cada pieza del equipo instalada en el mismo. ® Intel Server System SR1560SF Service Guide...
Deseche las baterías respetando la normativa local. No intente recargar la batería. No intente desmontar, pinchar o causar cualquier otro desperfecto a una batería. ® Intel Server System SR1560SF Service Guide...
Page 153
Precaución Para evitar el riesgo de la exposición a radiaciones o de daños personales: • No abra la caja de ningún periférico o dispositivo láser • Los periféricos o dispositivos láser no pueden ser reparados por el usuario • Haga que el fabricante los repare ® Intel Server System SR1560SF Service Guide...
Page 154
® Intel Server System SR1560SF Service Guide...
Need help?
Do you have a question about the SR1560SFHS - Server System - 0 MB RAM and is the answer not in the manual?
Questions and answers