Alert Startup Delay
This setting is used to configure the time in seconds to delay sending out alerts after a system power
up or reset.
The number of seconds allowed is between 60 and 255. Zero indicates no delay.
PEF Action Global Settings
This set of check boxes globally enables PEF actions that can occur when an event filter is
triggered. For a filter to trigger a particular chassis action (power cycle, reset, power down, or
diagnostic interrupt) the global setting must be enabled and the specific chassis action must be
selected for the filter. The chassis actions are configured in the screen that appears after the user
clicks Next.
The check boxes allow enabling or disabling of the following:
Power Cycle: This check box globally enables / disables the Power Cycle action when an event
filter is triggered. The action is enabled when the box is checked.
Reset: This check box globally enables / disables the system reset action when an event filter is
triggered. The action is enabled when the box is checked.
Power Down: This check box globally enables / disables the system power down action when
an event filter is triggered. The action is enabled when the box is checked.
Diagnostic Interrupt: This check box globally enables / disables a diagnostic (non-maskable)
interrupt when an event filter is triggered. The action is enabled with the box is checked.
Alert: This check box globally enables / disables alerts when an event filter is triggered. The
action is enabled when the box is checked.