Page 1
® Intel Server System SR1695GPRX Service Guide ® A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/ Products Intel Order Number G11460-003...
Page 2
Intel products are not designed, intended or authorized for use in any medical, life saving, or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur.
Safety Information Important Safety Instructions Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the ® Intel Server Deployment Toolkit CD and/or at, http://www.intel.com/support/motherboards/server/sb/cs-010770.htm.
Page 4
® Intel Server System SR1695GPRX Service Guide...
Take care to grip with, but not squeeze, the pliers or other tool you use to remove a jumper, or you may bend or break the pins on the board. ® Intel Server System SR1695GPRX Service Guide...
Page 6
® Intel Server System SR1695GPRX Service Guide...
BIOS update, and reset the password or CMOS. Information about the ® specific BIOS settings and screens is available in the Intel Server Board S3420GPRX Technical Product Specification. See the table below for a link to the Technical Product Specification.
Attention document (This document) • No power cord ® Your Intel Server System SR1695GPRX does not ship with the following items. You must add the following hardware to make this system operational: • Processors • Memory – DDR3 800/1066/1333 MT/s ECC Registered DIMM OR ECC unbuffered DIMM •...
Accessories or other Intel Spares and Configuration Guide server products This is available from your Intel field representative or on the Server Configurator Tool at: http://www.intel.com/p/en_US/support/highlights/server/s3420gp Hardware (peripheral For the Tested Hardware Operating Systems List, you can go to the ®...
Page 10
Server System References For this Information or Use this Document or Software Software For diagnostics test Diagnostics software http://www.intel.com/p/en_US/support/highlights/server/s3420gp ® Intel Server System SR1695GPRX Service Guide...
About this Manual ........................ vii Manual Organization ......................vii Product Contents .........................viii ® Intel Server System SR1695GPRX Contents ............viii Server System References ....................ix Chapter 1: Server System Features ................1 Chassis Component Identification ..................4 System Front Panel (SR1695GPRX) ................4 System Rear ........................
Page 12
Installing a SAS or SATA Hot-swap Hard Disk Drive ..........39 Removing a SAS or SATA Hot-swap Hard Disk Drive ..........42 Installing or Removing a Slimline Optical Drive (SR1695GPRX) ........42 Installing a Slimline Optical Drive ................42 Installing or Replacing a PCIe* Riser Card ................. 45 Replacing a PCIe* Riser Card ..................
Page 13
Removing the Power Supply ..................60 Installing the Power Supply ..................61 Replacing a System Fan (SR1695GPRX) ................62 Replacing the System Blower Fans (SR1695GPRX) ..........62 Replacing the Rotor Fan ....................64 Installing and Removing the Rack Handle ................66 Installing the Rack Handle ...................66 Removing the Rack Handle ..................66...
Page 14
Información de seguridad del servidor ..............110 Advertencias y precauciones sobre seguridad ............110 Aplicaciones y usos previstos ................... 111 Selección de la ubicación ..................112 Manipulación del equipo ................... 112 Advertencias de alimentación y eléctricas ..............112 ® Intel Server System SR1695GPRX Service Guide...
Page 15
Server Issue Report Form ............151 Board/Chassis Information ..................151 DIMM Configuration ....................151 Operating System Information ...................152 Add-in Card, Peripheral, Video, NIC ................152 Hard Drive Information ....................153 Management Information ...................153 Complete Problem Description ..................153 ® Intel Server System SR1695GPRX Service Guide xvii...
Page 16
® xviii Intel Server System SR1695GPRX Service Guide...
Page 17
® Figure 1. Intel Server System SR1695GPRX ................. 1 Figure 2. Front Controls and LEDs (SR1695GPRX) ..............4 Figure 3. Back Panel Connectors....................8 Figure 4. System Components (SR1695GPRX) ..............12 Figure 5. S3420GPRX Connector and Component Locations ..........14 Figure 6.
Page 18
Figure 43. Installing the Power Supply into the Server System..........61 Figure 44. Removing Fan from the Server System (SR1695GPRX) ........63 Figure 45. Installing Fan into the Server System (SR1695GPRX) ......... 64 Figure 46. Replacing the Rotor Fan..................65 Figure 47.
Page 19
List of Tables ® Table 1. Intel Server System SR1695GPRX Feature Summary ..........2 Table 2. Front Control Button Function ..................4 Table 3. Front LED Indicator Functions ..................5 Table 4. SSI Power LED Operation ................... 5 Table 5. System Status LED Operation ..................6 Table 6.
Page 20
® xxii Intel Server System SR1695GPRX Service Guide...
Table 1 summarizes the features of the server system. ® Table 1. Intel Server System SR1695GPRX Feature Summary Feature Description • Dimensions 1.69 inches high (43.00 millimeters) (SR1695GPRX) • 17.76 inches wide, without rails (451.17 millimeters) • 18.97 inches wide, with rails (482 millimeters) •...
Page 23
Support for four 2.5” or 3.5” serial SATA II hard drives with SW Drive Support RAID 0, 1, 5, and 10. • A slimline optical device is supported. ® • Up to four SAS hard drives through optional Intel SAS Entry RAID Module card. • ® RAID Support Intel Embedded Server RAID Technology II through onboard SATA connectors provides SATA RAID 0, 1, and 10.
C. Power/Sleep LED D. System NIC 5 Activity LED G. System Status LED I. USB 2.0 Connectors Figure 2. Front Controls and LEDs (SR1695GPRX) Table 2. Front Control Button Function Power/Sleep Button Toggles the system power on/off. This button also functions as a Sleep Button if enabled by an ACPI- compliant operating system.
System power is on but the BIOS has not yet initialized the chipset. S1 Sleep ACPI Blink DC power is still on. The operating system has saved context and gone into a level of low-power state. ® Intel Server System SR1695GPRX Service Guide...
4. Non-critical threshold crossed – Temperature, voltage, power nozzle, power gauge, and PROCHOT2 (Therm Ctrl) sensors. 5. Battery failure. 6. Predictive failure when the system has redundant power supplies. ® Intel Server System SR1695GPRX Service Guide...
Page 27
LED will be solid on, both amber and green. Once BMC initialization has completed, the status LED will stay green solid on. If power button is pressed before BMC initialization completes, the system will not boot to POST. ® Intel Server System SR1695GPRX Service Guide...
The following table provides the LED information. Table 6. NIC LED Descriptions LED State LED State NIC State Green LAN link is not established. LAN link is established. Blinking LAN activity is occurring. ® Intel Server System SR1695GPRX Service Guide...
Page 29
Table 6. NIC LED Descriptions LED State LED State NIC State 10 Mbit / sec data rate is selected Green 100 Mbit / sec data is selected Yellow 1000 Mbit / sec data rate is selected ® Intel Server System SR1695GPRX Service Guide...
Note: Each drive can consume up to 17 W of power. Drives must be specified to run at a maximum ambient temperature of 45 ° ® Note: The Intel Server System SR1695GPRX does not support all Serial ATA (SATA) hard drives. See “Server System References” for an Internet link to a list of supported hardware.
Note: The Intel Server System SR1695GPRX does not support all slimline optical drives. Refer to the table in Preface for an Internet link to a list of supported hardware. Intel provides accessory kits for these drives. For installation instructions for an optical drive, see “Installing or Removing a Slimline...
Server Board G. System Blowers (2) Power Supply Front Panel Hard Drive Bays Rotor Fan Slimline Optical Drive Bay PCIe* Riser Assembly BBU Support Rack Handles Processor Air Duct Figure 4. System Components (SR1695GPRX) ® Intel Server System SR1695GPRX Service Guide...
HH. Internal USB connector ® DIMM Slots II. Intel RMM3 Lite System FAN 3 JJ. Front Panel Connector System FAN 2 KK. Internal Serial Port B CPU Socket Figure 5. S3420GPRX Connector and Component Locations ® Intel Server System SR1695GPRX Service Guide...
Rack and Cabinet Mounting Options The chassis was designed to support 19 inches wide by up to 30 inches deep server cabinets. The system supports the following Intel rack mount options: • A basic slide rail kit (Product order code – AXXBASICRAIL) is designed to mount the chassis into a standard (19 inches by up to 30 inches deep) EIA-310D compatible server cabinet.
Server Board S3420GPRX supports one Intel Xeon 3400 processor series with 95 W Thermal Design Power (TDP). ® ® Intel Server Board S3420GPRX can also support Intel Core i3 processor. For a complete list of supported processors, see the links under “Server System References”. Memory ®...
Page 37
DIMM timings (RAS latency, CAS latency, etc.). ® ® The Intel SAS Entry RAID Module option is enabled by default once the Intel Entry RAID Module. ® Intel Server System SR1695GPRX Service Guide...
Page 38
® Intel Server System SR1695GPRX Service Guide...
You can run BIOS Setup with or without an operating system ® present. See the links under “Server System References” for a link to the Intel Server Board S3420GPRX Technical Product Specification where you will find details about specific BIOS setup screens.
If “No” is selected and <Enter> is pressed, or <Esc> is pressed, the user is returned to where they were before <F9> was pressed without affecting any existing field values. ® Intel Server System SR1695GPRX Service Guide...
Press <F2> Key if you want to run SETUP 2. Write down the current settings in the BIOS Setup program. Note: Do not skip Step 2. You need these settings to configure your server at the end of the procedure. ® Intel Server System SR1695GPRX Service Guide...
1. Power down and unplug the system from the AC power source. 2. Move the recovery jumper at JIF3 from the spare location at pins 2 and 3 to cover pins 1 and 2. Refer to the following figure. ® Intel Server System SR1695GPRX Service Guide...
“clear” position clears both passwords. Before a new password(s) is set, you must restore the password clear jumper to its original position. 1. Power down the system and disconnect the AC power. ® Intel Server System SR1695GPRX Service Guide...
2. Open the server chassis. For instructions, see your server chassis documentation. 3. Move the jumper from the default operating position (covering pins 1 and 2) to the reset / clear position (covering pins 2 and 3). ® Intel Server System SR1695GPRX Service Guide...
Integrated BMC into an update mode, allowing the firmware to load safely onto the flash device. In the unlikely event the Integrated BMC firmware update process fails (due to the Integrated BMC not being in the proper update state), the server ® Intel Server System SR1695GPRX Service Guide...
Page 46
9. Move jumper from the enabled position (covering pins 2 and 3) to the disabled position (covering pins 1 and 2). 10. Close the server chassis. 11. Reconnect the AC cord and power up the server. ® Intel Server System SR1695GPRX Service Guide...
® Intel Server System SR1695GPRX are hot-swappable. Before removing or installing any non-hot-swappable component in this server system, you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and unplug the AC power cord from the system or wall outlet.
3. Push rearward on the blue grip point at the front of the server. 4. Slide the cover back until it stops and then lift the cover upward to remove it. See letter “C”. EP0004 Figure 11. Removing the Server System Cover ® Intel Server System SR1695GPRX Service Guide...
The system requires the use of an air duct to direct airflow and sustain appropriate air pressure. Always operate your server system with the air duct in place. The air duct is required for proper airflow within the server system. ® Intel Server System SR1695GPRX Service Guide...
3. Remove the server system cover. For instructions, see “Removing the Server System Cover”. 4. Lift the processor air duct from its location behind the two system blower fans. EP0006 Figure 13. Removing the Processor Air Duct ® Intel Server System SR1695GPRX Service Guide...
DIMM B2 starting from the center of the board. See “Memory” for a discussion of the memory requirements and options. See “Server System References” for a link to the list of tested DIMMs. ® Intel Server System SR1695GPRX Service Guide...
11. Install the server system cover. For instructions, see “Installing the Server System Cover”. Removing DIMMs To remove a DIMM, follow these steps: 1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information”. ® Intel Server System SR1695GPRX Service Guide...
Page 53
6. Holding the DIMM by the edges, lift it from the socket, and store it in an anti-static package. 7. Install the server system cover. For instructions, see “Installing the Server System Cover”. ® Intel Server System SR1695GPRX Service Guide...
9. Raise the CPU load plate. 10. Remove the processor. 11. If installing a replacement processor, see “Installing the Processor”. Otherwise, install the protective socket cover over the empty processor socket and then reinstall the chassis cover. ® Intel Server System SR1695GPRX Service Guide...
Figure 16. Lifting the Processor Socket Handle 5. Push the rear tab with your finger to slightly lift the front of the load plate. Raise the load plate completely. Raise the CPU load plate (see Figure 17). ® Intel Server System SR1695GPRX Service Guide...
Caution: Do not touch the socket pins; they are very sensitive and easily damaged. 6. Remove the processor from the packaging box and remove the protective shipping cover. See Figure 18. AF003189 Figure 18. Removing the Shipping Cover ® Intel Server System SR1695GPRX Service Guide...
9. Remove the protective socket cover. See Figure AF003368 Figure 20. Removing the Protective Socket Cover Note: Retain the protective socket cover for use when removing a processor that will not be replaced. ® Intel Server System SR1695GPRX Service Guide...
Figure 21. Do not fully tighten one screw before tightening another. 5. Gradually and equally tighten each captive screw in the same order until each is firmly tightened. AF003369 Figure 21. Installing the Heat Sink ® Intel Server System SR1695GPRX Service Guide...
“Installing the Server System Cover”. Installing and Removing a Hot-swap Hard Drive ® You can install up to two fixed SATA drives in the Intel Server System SR1695GPRX. “Server System References” for a link to a list of supported hardware.
6. Align the holes in the drive to the holes in the drive carrier and attach it to the carrier with the screws that were attached to the drive blank. AF003303 Figure 23. 2.5 HDD Installation ® Intel Server System SR1695GPRX Service Guide...
Do not push on the black drive carrier lever until the lever begins to close by itself. 8. When the black drive carrier lever begins to close by itself, push on it to lock the drive assembly into place. AF003305 Figure 25. Locking the drive assembly ® Intel Server System SR1695GPRX Service Guide...
To maintain proper system cooling, if you do not install a device at this location, you must install the provided filler blank. Installing a Slimline Optical Drive 1. Remove the slimline drive bay filler blank, if installed. ® Intel Server System SR1695GPRX Service Guide...
3. Screw the latch to the optical drive, and plug in the composed SATA/SATA Power cable, which is shipped in system package. AF003312 Figure 27. Attaching the Brackets to the Optical Drive 4. Lead the SATA/SATA Power cable through the optical drive bay before inserting the drive. ® Intel Server System SR1695GPRX Service Guide...
6. Connect the SATA cable connector to SATA port 4 or 5 on server board. 7. Connect the SATA power connector to P6 connector from system power supply. EP0009 Figure 28. Installing the Optical Drive into the Server System ® Intel Server System SR1695GPRX Service Guide...
6. Remove any add-in cards from the PCIe* Riser connector. For instructions, see “Removing a PCI Add-in Card”. 7. Remove the screw that attaches the riser card to the riser assembly. Save these screws to be used later. ® Intel Server System SR1695GPRX Service Guide...
5. Remove the PCIe* Riser assembly. 6. Remove any add-in cards from the PCIe* Riser connector. For instructions, see “Removing a PCI Add-in Card”. 7. Use the screw to attach the riser card to the riser assembly. ® Intel Server System SR1695GPRX Service Guide...
AC power cord from the system or wall outlet. Installing a PCI Add-in Card 1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information”. ® Intel Server System SR1695GPRX Service Guide...
4. Remove the PCIe* Riser assembly. For instructions, see “Replacing a PCIe* Riser Card”. 5. Remove the screw at the rear of the riser assembly. See letter “A” in Figure Save this screw. You will use it later. ® Intel Server System SR1695GPRX Service Guide...
10. Install the processor air duct. For instructions, see “Installing the Processor Air Duct”. 11. Install the server system cover. For instructions, see “Installing the Server System Cover”. 12. Plug all peripheral devices and the AC power cable into the server. ® Intel Server System SR1695GPRX Service Guide...
2. Attach the standoffs to the server board (see letter “A”) and attach the I/O shield gasket to the module (see letter “B”). 3. Attach the I/O expansion module(s) to the server board (see letter “C”). ® Intel Server System SR1695GPRX Service Guide...
1. Remove the I/O expansion module(s) from the server board (see letter “A”). 2. Remove the standoffs from the server board (see letter “B”). 3. Install the I/O expansion module cover into the system back panel (see letter “C”). ® Intel Server System SR1695GPRX Service Guide...
Removing the RMM3 Lite 1. Remove the PCI riser assembly. For instructions, see “Replacing a PCIe* Riser Card”. 2. Disconnect the RMM3 Lite from the server board RMM3 Lite connector (J2D1) as shown in Figure ® Intel Server System SR1695GPRX Service Guide...
2. Disconnect all cables from the backplane board. 3. Remove two screws on the top of backplane bracket (see letter “B”). 4. Pull out the backplane assembly vertically from the chassis (see letter “C”). ® Intel Server System SR1695GPRX Service Guide...
2. Tighten two screws to lock the backplane assembly in position (see letter “B”). 3. Connect data/power cables to the backplane connectors. 4. Engage hard drives back to the backplane (see letter “C”). ® Intel Server System SR1695GPRX Service Guide...
7. Remove the nine screws from the server board (see letter “A”) and lift the server board from the server system (see letter “B”). EP0023 Figure 39. Removing the Server Board 8. Install the replacement server board. See “Installing the Server Board” on page ® Intel Server System SR1695GPRX Service Guide...
4. Re-connect the system fan cables to server board. 5. Re-connect all SATA cables to the server board. 6. Install the PCI riser assembly. 7. Install the memory, processor heat sinks, and processors. 8. Install the system air duct. ® Intel Server System SR1695GPRX Service Guide...
Cover”. 4. Remove the server's cover and locate the battery. See Figure 5. Pull back gently on the metal tab at the top of the battery. 6. Remove the battery from its socket. ® Intel Server System SR1695GPRX Service Guide...
8. Remove the new lithium battery from its package, and, being careful to observe the correct polarity, insert it in the battery socket. 9. Close the chassis. 10. Run the BIOS Setup utility to restore the configuration settings. ® Intel Server System SR1695GPRX Service Guide...
Replacing the Power Supply (SR1695GPRX) Removing the Power Supply You can replace the power supply if it fails or if one of the fans integrated into it fails. To replace the power supply, use the following instructions. 1. Disconnect the power cord (see letter “A”).
1. Insert the replacement power supply module into the power supply cage and push hard until it clicks into place (see letter “A”). 2. Connect the power cord (see letter “B”). EP0029 Figure 43. Installing the Power Supply into the Server System. ® Intel Server System SR1695GPRX Service Guide...
Use the following steps to replace a system blower fan or the PCI cooling fan. Replacing the System Blower Fans (SR1695GPRX) 1. Observe the safety and ESD precautions at the beginning of this book. See “Safety...
7. Lift the fan from the system (see letter “C” in Figure 44). EP0017 Figure 44. Removing Fan from the Server System (SR1695GPRX) 8. Install the replacement fan into the chassis (see letter “A” in Figure 45), using the two screws you removed previously.
EP0013 Figure 45. Installing Fan into the Server System (SR1695GPRX) 11. Install the server system cover. For instructions, see “Installing the Server System Cover”. 12. Plug all peripheral devices and the AC power cable into the server. Replacing the Rotor Fan 1.
2. Repeat step 1 on the opposite side of the server. Removing the Rack Handle 1. Remove the three screws holding the rack handle in place, and remove the rack handle from the server system. AF003327 Figure 48. Removing the Rack Handle ® Intel Server System SR1695GPRX Service Guide...
Removing and Installing the Front Bezel ® The front bezel is available as an optional accessory for the Intel Server System SR1695GPRX. Removing the Front Bezel 1. Unlock the bezel with the key and pull the bezel from the server system.
For example, the PCI cooling fan cable is labeled with the letter “C” both where it connects to the server board and at the PCI cooling fan itself. ® Intel Server System SR1695GPRX Service Guide...
Cable Routing (SR1695GPRX) Power Supply Server Board Front Panel USB SGPIO Backplane Optical Drive EP0020 Backplane Figure 51. Cable Routing (SR1695GPRX) ® Intel Server System SR1695GPRX Service Guide...
400-W Single Power Supply Output Voltages Table 9 lists the total wattage available from the power subsystem for each voltage. For information about calculating the power usage for your configuration, see SR1695GPRX Power Budget Tool. Table 9. Power Supply Output Capability...
Vibration, unpackaged 5 Hz to 500 Hz, 2.20 g RMS random Shock, operating Half sine, 2 g peak, 11 mSec ® +/-15kV except I/O port +/-8KV per Intel Environmental test specification System Cooling 2050 BTU/hour Requirement in BTU/Hr EMI operating Required to meet EMI emission requirements, tested as part of system ®...
See “Server System References” for links to the tested component lists. Hardware Diagnostic Testing This section provides a more detailed approach to identifying a hardware problem and locating its source. ® Intel Server System SR1695GPRX Service Guide...
• Characters on the screen appear distorted or incorrect. • System cooling fans do not rotate. • Diskette drive activity light does not light. • Hard disk drive activity light does not light. ® Intel Server System SR1695GPRX Service Guide...
Are the brightness and contrast controls on the video monitor properly adjusted? • Is the video monitor signal cable properly installed? • Does this video monitor work correctly if plugged into a different system? • Is the onboard video controller enabled in the BIOS? ® Intel Server System SR1695GPRX Service Guide...
Is the power-on light lit? If not, see “Power Light Does Not Light”. • Are any other front panel LEDs lit? • Have any of the fan motors stopped? Use the server management subsystem to check the fan status. ® Intel Server System SR1695GPRX Service Guide...
Make sure the hub port is configured for the same duplex mode as the network controller. • Make sure the correct networking software is installed. • If you are directly connecting two servers (without a hub), you will need a crossover cable. ® Intel Server System SR1695GPRX Service Guide...
Before installing a PCI card, you should always: • Turn off the server power by using the power button on the front of the system. • Unplug the AC power cord(s) from the server. ® Intel Server System SR1695GPRX Service Guide...
If you are experiencing any of the above symptoms that might indicate voltage spikes on the power line, you may want to install a surge suppressor between the power outlet and the system power cord. ® Intel Server System SR1695GPRX Service Guide...
Devices are not Recognized under Device Manager (Microsoft Windows* Operating System) ® The Microsoft Windows* operating systems do not include all of the drivers for the Intel chipsets, onboard NICs, and other components. See “Server System References” for a link to the current drivers and chipset files.
Page 102
® Intel Server System SR1695GPRX Service Guide...
5. Provide some electrostatic discharge (ESD) protection by wearing an antistatic wrist strap attached to chassis ground of the system-any unpainted metal surface-when handling components. 6. Do not operate the system with the chassis covers removed. ® Intel Server System SR1695GPRX Service Guide...
Page 104
Danger of explosion if the battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the equipment manufacturer. Dispose of used batteries according to manufacturer's instructions. ® Intel Server System SR1695GPRX Service Guide...
Netzgerät ein eigenes Netzkabel. Der Wechselstrom des Systems wird durch den Ein-/Aus-Schalter für Gleichstrom nicht ausgeschaltet. Ziehen Sie jedes Wechselstrom-Netzkabel aus der Steckdose bzw. dem Netzgerät, um den Stromanschluß des Systems zu unterbrechen. ® Intel Server System SR1695GPRX Service Guide...
Page 106
4. Bringen Sie die Verschlußeinrichtung (Padlock) wieder an und schließen Sie diese, um ein unerlaubtes Öffnen des Systems zu verhindern. 5. Schließen Sie alle externen Kabel und den AC Stromanschlußstecker Ihres Systems wieder an. ® Intel Server System SR1695GPRX Service Guide...
Français Le bloc d'alimentation de ce produit ne contient aucune pièce pouvant être réparée par l'utilisateur. Ce produit peut contenir plus d'un bloc d'alimentation. Veuillez contacter un technicien qualifié en cas de problème. ® Intel Server System SR1695GPRX Service Guide...
Page 108
Procédez comme suit: 1. Si un cadenas a été installé sur à l'arrière du système, déverrouillez-le et retirez-le. 2. Retirez toutes les vis des panneaux et mettez-les dans un endroit sûr. 3. Retirez les panneaux. ® Intel Server System SR1695GPRX Service Guide...
Page 109
• "Muni d'une prise murale correctement mise à la terre. • "Suffisamment spacieux pour vous permettre d'accéder aux câbles d'alimentation (ceux-ci étant le seul moyen de mettre le système hors tension). ® Intel Server System SR1695GPRX Service Guide...
- o a cualquier tipo de superficie de metal sin pintar. 6. No ponga en marcha el sistema si se han extraído las tapas del chasis. ® Intel Server System SR1695GPRX Service Guide...
Page 111
Existe peligro de explosión si la pila no se cambia de forma adecuada. Utilice solamente pilas iguales o del mismo tipo que las recomendadas por el fabricante del equipo. Para deshacerse de las pilas usadas, siga igualmente las instrucciones del fabricante. ® Intel Server System SR1695GPRX Service Guide...
Page 112
• "Provisto de una toma de tierra correctamente instalada. • "Provisto de espacio suficiente como para acceder a los cables de alimentación, ya que éstos hacen de medio principal de desconexión del sistema. ® Intel Server System SR1695GPRX Service Guide...
1. Aprire e rimuovere il lucchetto dal retro del sistema qualora ve ne fosse uno installato. 2. Togliere e mettere in un posto sicuro tutte le viti delle coperture. 3. Togliere le coperture. ® Intel Server System SR1695GPRX Service Guide...
Page 114
• "Dotata di una presa a muro correttamente installata. • "Dotata di spazio sufficiente ad accedere ai cavi di alimentazione, i quali rappresentano il mezzo principale di scollegamento del sistema. ® Intel Server System SR1695GPRX Service Guide...
Indicates the presence of a hazard that may result in serious personal injury if the WARNING is ignored. Indicates potential hazard if indicated information is ignored. Indicates shock hazards that result in serious injury or death if safety instructions are not followed. ® Intel Server System SR1695GPRX Service Guide...
Provided with a properly grounded wall outlet. • Provided with sufficient space to access the power supply cord(s), because they serve as the product's main power disconnect. Equipment Handling Practices Reduce the risk of personal injury or equipment damage: ® Intel Server System SR1695GPRX Service Guide...
Disconnect all cables and telecommunication lines that are connected to the compute module. • Retain all screws or other fasteners when removing access cover(s). Upon completion of accessing inside the product, refasten access cover with original screws or fasteners. ® Intel Server System SR1695GPRX Service Guide...
Do not attempt to recharge a battery. Do not attempt to disassemble, puncture, or otherwise damage a battery. Cooling and Airflow Caution: Carefully route cables as directed to minimize airflow blockage and cooling problems. ® Intel Server System SR1695GPRX Service Guide...
Komponenten, die im vorliegenden Handbuch angegeben werden. Die Verwendung anderer Produkte oder Komponenten führt zum Erlöschen der UL-Zulassung und anderer Genehmigungen für das Produkt. Dadurch kann das Produkt gegen Produktbestimmungen verstoßen, die im Verkaufsland gelten. ® Intel Server System SR1695GPRX Service Guide...
Dieses Produkt wurde in seiner Eigenschaft als IT-Gerät getestet, das in Büros, Schulen, Computerräumen und ähnlichen öffentlichen Räumlichkeiten installiert werden kann. Die Eignung dieses Produkts für andere Einsatzbereiche als IT (z. B. Medizin, Industrie, Alarmsysteme oder Prüfgeräte) kann u. U. weitere Tests erfordern. ® Intel Server System SR1695GPRX Service Guide...
Verwenden Sie mechanische oder andere geeignete Hilfsmittel zum Transportieren oder Anheben von Geräten. • Entfernen Sie alle Komponenten, die sich leicht abnehmen lassen, um das Gewicht zu reduzieren und die Handhabung zu erleichtern. ® Intel Server System SR1695GPRX Service Guide...
Typ entspricht. Jedes Netzteil im System muß über ein eigenes Netzkabel angeschlossen werden. Einige Netzteile von Intel Servern verwenden Nullleitersicherungen. Vorsicht ist geboten im Umgang mit Netzteilen, welche Nullleitersicherungen verwenden, um das Risiko eines elektrischen Schlages zu vermeiden Das Netzteil in diesem Produkt enthält keine Teile, die vom Benutzer gewartet werden...
Ausbau aus dem Server mit der Bauelementseite nach oben auf eine geerdete, statisch entladene Unterlage.Verwenden Sie dazu, sofern verfügbar, eine leitfahige Schaumstoffunterlage, aber niche die Schutzhülle der Platine. Ziehen Sie die Platine nicht über eine Fläche. ® Intel Server System SR1695GPRX Service Guide...
• Öffnen Sie keinesfalls das Gehäuse von Laser-Peripheriegeräten oder Laser- Komponenten. • Laser-Peripheriegeräte oder -Komponenten besitzen keine für den Benutzer wartungsbedürftigen Teile. • Schicken Sie das Gerät für Wartungsarbeiten an den Hersteller zurück. ® Intel Server System SR1695GPRX Service Guide...
Français Consignes de sécurité sur le serveur ® ® Ce document s’applique aux cartes serveur Intel , au châssis de serveur (sur pieds et Intel sur rack) et aux périphériques installés. Pour réduire les risques de dommages corporels, d’électrocution, d’incendie et de dommages matériels, lisez ce document et respectez tous les avertissements et précautions mentionnés dans ce guide avant d’installer ou de mettre...
Dans les régions sujettes aux orages magnétiques, nous vous recommandons de brancher votre système à un suppresseur de surtension et de déconnecter les lignes de télécommunication de votre modem pendant les orages. • Équipé d’une prise murale reliée à la terre. ® Intel Server System SR1695GPRX Service Guide...
• Utilisez l’assistance mécanique ou toute autre assistance appropriée lorsque vous déplacez et soulevez le matériel. • Pour réduire le poids en vue de faciliter la manipulation, retirez tout composant amovible. ® Intel Server System SR1695GPRX Service Guide...
Vous devez les débrancher avant d’ouvrir le châssis, d’ajouter ou de supprimer un composant non connectable à chaud. Les alimentations de certains serveurs Intel sont munies de doubles fusibles pôle/neutre: veuillez observer les précautions d'usage afin d'éviter tout risque d'eléctrocution.
Afin de permettre une ventilation et un refroidissement corrects, ne mettez le système en marche que lorsque les panneaux du châssis sont en place. L’utilisation du système sans les panneaux peut endommager les composants système. Pour installer les panneaux : ® Intel Server System SR1695GPRX Service Guide...
Retournez-les au fabricant en cas de problème. Español Información de seguridad del servidor ® Este documento se aplica a las tarjetas de servidor de Intel , los gabinetes de servidor de ® Intel (montaje en rack y en pedestal) y los dispositivos periféricos. Para reducir el riesgo de daños corporales, descargas eléctricas, fuego y en el equipo, lea este documento y...
Es posible que sea necesario llevar a cabo una evaluación adicional para comprobar si este producto es apropiado para otras categorías de productos y entornos además de las aplicaciones informáticas (por ejemplo, soluciones médicas, industriales, residenciales, sistemas de alarma y equipos de pruebas). ® Intel Server System SR1695GPRX Service Guide...
CA estén desenchufado antes de abrir le gabinete, agregar o extraer cualquier componente que no es de conexión en funcionamiento. Algunas fuentes de alimentación de electricidad de los servidores de Intel utilizan el polo neutral del fuselaje. Para evitar riesgos de choques eléctricos use precauciones al ®...
A no ser que esté instalando o extrayendo un componente de conexión en funcionamiento, deje que el sistema se enfríe antes de abrir las cubiertas. Para que no llegue a tocar los componentes que estén calientes cuando esté realizando una instalación ® Intel Server System SR1695GPRX Service Guide...
Para instalar las cubiertas: • Compruebe primero que no ha dejado herramientas o piezas sueltas dentro del sistema. • Compruebe que los cables, tarjetas adicionales y otros componentes están instalados correctamente. ® Intel Server System SR1695GPRX Service Guide...
Page 135
Precaución: Para evitar el riesgo de la exposición a radiaciones o de daños personales: • No abra la caja de ningún periférico o dispositivo láser • Los periféricos o dispositivos láser no pueden ser reparados por el usuario • Haga que el fabricante los repare. ® Intel Server System SR1695GPRX Service Guide...
(or higher) and operating at the same (or higher) speed as the microprocessor used on this server board. The final configuration of your end system product may require additional EMC compliance testing. For more information, please contact your local Intel representative.
This server system has been tested and verified to comply with the following ® electromagnetic compatibility (EMC) regulations when installed in a compatible Intel host system. For information on compatible host system(s) refer to Intel's Server Builder Web site or contact your local Intel representative. ®...
Product Ecology Requirements Intel has a system in place to restrict the use of banned substances in accordance with world wide product ecology regulatory requirements. Suppliers Declarations of Conformity to the banned substances must be obtained from all suppliers; and a Material Declaration Data Sheet (MDDS) must be produced to illustrate compliance.
Page 144
— CE DOC (Europe) — CB Certificate & Report (International) Note: CB to include all CB national deviations) Certification marks to be visible on power supply. Power supply to comply with the Intel power supply specification. • Peripheral Devices (e.g. Disk Drives, CD ROMs) —...
GOST R Certification / License (Russia) • KCC Certification (Korea) • IRAM Certification (Argentina) • Ecology Declaration (International) Product Regulatory Compliance Markings ® This Intel server system product is provided with the following regulatory marks ® Intel Server System SR1695GPRX Service Guide...
Ctick Mark Australia / NZ N232 CANADA ICES-003 CLASS A EMC Marking Canada CE Mark Europe GS Mark Germany VCCI Mark Japan KCC Mark Korea 인 증번호 : CPU-SR1695 (A) GOST Mark Russia MO04 ® Intel Server System SR1695GPRX Service Guide...
Page 147
“Apparaten skall anslutas till jordat uttag, när den ansluts till ett nätverk.” Finnish on line 3: “Laite on liitettävä suojamaadoituskoskettimilla varustettuun pistorasiaan.” English on line 4: “Connect only to a properly earth grounded outlet.” ® Intel Server System SR1695GPRX Service Guide...
Page 148
修之前應斷開兩 (2)條電源系統電纜。 German: Dieses Geräte hat mehr als ein Stromkabel. Um eine Gefahr des elektrischen Schlages zu verringern trennen sie beide (2) Stromkabeln bevor Instandhaltung. WEEE WEEE Marking Marking China RoHS China RoHS ® Intel Server System SR1695GPRX Service Guide...
Page 149
This notice is required by California Code of Regulations, Title 22, Division 4.5, Chapter 33: Best Management Practices for Perchlorate Materials. This product / part includes a battery which contains Perchlorate material. ® Intel Server System SR1695GPRX Service Guide...
Page 150
Regulatory Compliance Region Marking Standard icon for Power button Should be attached on power button ® Intel Server System SR1695GPRX Service Guide...
All cables used to connect to peripherals must be shielded and grounded. Operation with cables, connected to peripherals, that are not shielded and grounded may result in interference to radio and TV reception. ® Intel Server System SR1695GPRX Service Guide...
Interference (VCCI) from Information Technology Equipment. If this is used near a radio or television receiver in a domestic environment, it may cause radio interference. Install and use the equipment according to the instruction manual. ® Intel Server System SR1695GPRX Service Guide...
Following is the RRL certification information for Korea. English translation of the notice above: 1. Type of Equipment (Model Name): On License and Product 2. Certification No.: On RRL certificate. Obtain certificate from local Intel representative 3. Name of Certification Recipient: Intel Corporation 4.
Page 154
® Intel Server System SR1695GPRX Service Guide...
“as is” unless specifically provided for otherwise in any software license accompanying the software. If any Product furnished by Intel which is the subject of this Limited Warranty fails during the warranty period for reasons covered by this Limited Warranty, Intel, at its option, will: •...
Limitations of Liability Intel's responsibility under this, or any other warranty, implied or expressed, is limited to repair, replacement, or refund, as set forth above. These remedies are the sole and exclusive remedies for any breach of warranty.
Telephone Support If you cannot find the information you need on Intel's World Wide Web site (http:// www.intel.com/), call your local distributor or an Intel Customer Support representative.
Page 158
® Intel Server System SR1695GPRX Service Guide...
Telephone All calls are billed per incident, levied in local currency at the applicable credit card exchange rate plus applicable taxes. (Intel reserves the right to change the pricing for telephone support at any time without notice). ® Before calling, fill out an Intel Server Issue Report Form.
Easter Island....Contact AT&T USA at 800 800 311. Once connected, dial 800 843 4481 Mainland and Juan .. Contact AT&T USA at 800 225 288. Once connected, dial 800 843 4481 ® Intel Server System SR1695GPRX Service Guide...
Page 161
Panama..Contact AT&T USA at 00 800 001 0109. Once connected, dial 800 843 4481 Paraguay ... 001 916 377 0114 Peru ... 001 916 377 0114 Uruguay..001 916 377 0114 Venezuela... Contact AT&T USA at 0 800 2255 288. Once connected, dial 800 843 4481 ® Intel Server System SR1695GPRX Service Guide...
Page 162
® Intel Server System SR1695GPRX Service Guide...
The diagnostic LED #7 is labeled as “MSB” (Most Significant Bit), and the diagnostic LED #0 is labeled as “LSB” (Least Significant Bit). In the following example, the BIOS sends a value of ACh to the diagnostic LED decoder. The LEDs are decoded as follows: ® IIntel Server System SR1695GPRX Service Guide...
Early processor initialization (flat32.asm) where system BSP is selected 0x10h Power-on initialization of the host processor (bootstrap processor) 0x11h Host processor cache initialization (including AP) 0x12h Starting application processor initialization 0x13h SMM initialization ® Intel Server System SR1695GPRX Service Guide...
Page 165
Detecting presence of memory 0x24h Programming timing parameters in the memory controller 0x25h Configuring memory parameters in the memory controller 0x26h Optimizing memory controller settings 0x27h Initializing memory, such as ECC init 0x28h Testing memory ® Intel Server System SR1695GPRX Service Guide...
Page 166
Resetting SATA bus and all devices 0x5Bh Detecting the presence of ATA device 0x5Ch Enable SMART if supported by ATA device 0x5Dh Reserved for ATA SMBUS 0x5Eh Resetting SMBUS 0x5Fh Reserved for SMBUS Local Console ® Intel Server System SR1695GPRX Service Guide...
Page 167
Enabling the keyboard 0x94h Clearing keyboard input buffer 0x95h Reserved for keyboard Mouse (only USB) 0x98h Resetting the mouse 0x99h Detecting the mouse 0x9Ah Detecting the presence of mouse 0x9Bh Enabling the mouse ® Intel Server System SR1695GPRX Service Guide...
Page 168
Boot Device Selection (BDS) 0xD0 Entered the Boot Device Selection phase (BDS) 0xD1 Return to last good boot device 0xD2 Set up boot device selection policy 0xD3 Connect boot device controller ® Intel Server System SR1695GPRX Service Guide...
Page 169
Driver Execution Environment (DXE) Core 0xE4h Entered EFI driver execution phase (DXE) 0xE5h Started dispatching drivers 0xE6h Started connecting drivers DXE Drivers 0xE7h Waiting for user input 0xE8h Checking password 0xE9h Entering BIOS setup 0xEAh Flash Update ® Intel Server System SR1695GPRX Service Guide...
Page 170
0XF4h Entering the sleep state 0XF5h1 Exiting the sleep state 0XF8h Operating system has requested EFI to close boot services has been cancelled Progress Code 0XF9h Resetting the keyboard 0xFAh Disabling the keyboard ® Intel Server System SR1695GPRX Service Guide...
____________________________________________________________________ ____________________________________________________________________ Board/Chassis Information Baseboard Revision - PBA#: _____________________________________________ Baseboard Serial Number: _______________________________________________ CPU Speed/Stepping/Spec: ______________________________________________ System BIOS Version: __________________________________________________ HSC Firmware Version: _________________________________________________ DIMM Configuration DIMM A1 MB and Vendor/part number: ___________________________________ ® IIntel Server System SR1695GPRX Service Guide...
In the space below, provide a complete description of the steps used to reproduce the problem or a complete description of where the problem can be found. Please also include any details on troubleshooting already done. ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ® Intel Server System SR1695GPRX Service Guide...
Page 174
____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ® Intel Server System SR1695GPRX Service Guide...
Need help?
Do you have a question about the SR1695GPRX and is the answer not in the manual?
Questions and answers