Cisco Unified Serviceability Alarms and CiscoLog Messages
If the Lua Instruction Threshold is set to 2000 and the internal threshold is 50%, this alarm will
2.
occur when the script has executed 1000 Lua instructions.
This alarm warns that the resources (either memory or Lua instructions) have crossed an internal mark,
where investigation into the consumption of those resources may be advisable to ensure the health of the
script.
History
Cisco Unified Communications
Release
8.5(1)
Facility/Sub-Facility
CCM_CALLMANAGER-CALLMANAGER
Cisco Unified Serviceability Alarm Definition Catalog
CallManager/CallManager
Severity
Error
Routing List
SDI
Sys Log
Event Log
Parameters
Device Name(String)
Script Name(String)
Script Function(String)
Script Type(String)
Reason Code(Enum)
Reason Text(String)
In Use Memory(UInt)
Memory Threshold (UInt)
In Use Lua Instructions(UInt)
Lua Instruction Threshold(UInt)
Enum Definitions - Reason Code
Value
1
2
OL-22523-01
Action
New alarm for this release.
Definition
InternalLuaInstructionsThreshold—The script exceeds the internal
threshold for the number of Lua instructions.
InternalMemoryThreshold—The script exceeds the internal threshold
for script memory usage.