Cisco MCS-7825-H3-IPC1 Service Manual page 157

Managed services guide
Table of Contents

Advertisement

Chapter 5
Cisco Unified Real-Time Monitoring Tool Tracing, PerfMon Counters, and Alerts
Table 5-1
Setting
Threshold Pane
Trigger alert when Over and
Under conditions get met
Value Calculated As Pane
Absolute, Delta, Delta
Percentage
Duration Pane
Trigger alert only when value
constantly...; Trigger alert
immediately
OL-22523-01
Counter Alert Configuration Parameters
Description
Check the box and enter the value that applies.
Over—Check this box to configure a maximum threshold that
must be met before an alert notification is activated. In the Over
value field, enter a value. For example, enter a value that equals
the number of calls in progress.
Under—Check this box to configure a minimum threshold that
must be met before an alert notification is activated. In the
Under value field, enter a value. For example, enter a value that
equals the number of calls in progress.
Tip
Click the radio button that applies.
Absolute—Choose Absolute to display the data at its current
status. These counter values are cumulative.
Delta—Choose Delta to display the difference between the
current counter value and the previous counter value.
Delta Percentage—Choose Delta Percentage to display the
counter performance changes in percentage.
Trigger alert only when value constantly...—If you want the
alert notification only when the value is constantly below or
over threshold for a desired number of seconds, click this radio
button and enter seconds after which you want the alert to be
sent.
Trigger alert immediately—If you want the alert notification to
be sent immediately, click this radio button.
Cisco Unified Communications Manager Managed Services Guide
Use these boxes in conjunction with the Frequency and
Schedule configuration parameters.
Performance Monitoring in RTMT
5-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Unified communications manager 8.5(1)

Table of Contents