Chapter 5
Cisco Unified Real-Time Monitoring Tool Tracing, PerfMon Counters, and Alerts
Table 5-1
Setting
Threshold Pane
Trigger alert when Over and
Under conditions get met
Value Calculated As Pane
Absolute, Delta, Delta
Percentage
Duration Pane
Trigger alert only when value
constantly...; Trigger alert
immediately
OL-22523-01
Counter Alert Configuration Parameters
Description
Check the box and enter the value that applies.
Over—Check this box to configure a maximum threshold that
•
must be met before an alert notification is activated. In the Over
value field, enter a value. For example, enter a value that equals
the number of calls in progress.
Under—Check this box to configure a minimum threshold that
•
must be met before an alert notification is activated. In the
Under value field, enter a value. For example, enter a value that
equals the number of calls in progress.
Tip
Click the radio button that applies.
Absolute—Choose Absolute to display the data at its current
•
status. These counter values are cumulative.
Delta—Choose Delta to display the difference between the
•
current counter value and the previous counter value.
Delta Percentage—Choose Delta Percentage to display the
•
counter performance changes in percentage.
Trigger alert only when value constantly...—If you want the
•
alert notification only when the value is constantly below or
over threshold for a desired number of seconds, click this radio
button and enter seconds after which you want the alert to be
sent.
Trigger alert immediately—If you want the alert notification to
•
be sent immediately, click this radio button.
Cisco Unified Communications Manager Managed Services Guide
Use these boxes in conjunction with the Frequency and
Schedule configuration parameters.
Performance Monitoring in RTMT
5-3