Threadkillingerror - Cisco MCS-7825-H3-IPC1 Service Manual

Managed services guide
Table of Contents

Advertisement

Chapter 6
Cisco Unified Serviceability Alarms and CiscoLog Messages
Recommended Action
Check the Cisco RIS Data Collector service parameter, Maximum Number of Processes and Threads, to
see if the parameter has been set to a low value. If it has been, set the value higher or use the default
value. Another possible action is that when a new Cisco product is integrated into Cisco Unified
Communications Manager (Cisco Unified CM), new processes or threads are added to the system. Even
in the normal process load situation, it's possible that the total number of processes and threads has
exceeded the configured or default value of the Cisco RIS Data Collector service parameter, Maximum
Number of Processes and Threads. Set that parameter to the maximum allowed value.
You can also review the details of this alarm to check the ProcessWithMostThreads description and the
ProcessWithMostInstances description to discover which processes have the most threads and the most
instances. Determine whether these values are reasonable for this process; if not, contact the owner of
the process for troubleshooting the reasons why the thread count or the number of process instances is
so high. It is also possible that Cisco RIS Data Collector sent a false alarm, which would indicate a defect
in the Cisco RIS Data Collector service.
To determine if this is the cause of the alarm - after you have checked all the other errors described here
- use RTMT to check the System object for performance counters Total Threads and Total Processes to
confirm that the values in those counters do not exceed the value configured in the Cisco RIS Data
Collector service parameter, Maximum Number of Processes and Threads. If the counters do not show
a value that is higher than what is configured in the service parameter, restart Cisco RIS Data Collector
service. If the alarm persists after restarting the service, go to Cisco Unified Serviceability and collect
trace logs (Trace > Configuration) for Cisco Syslog, Cisco RIS Data Collector, Cisco AMC Service, and
Cisco RIS Perfmon Logs and contact Cisco Technical Assistance Center (TAC) for detailed assistance.

ThreadKillingError

An error occurred when CMI tried to stop the CMI service.
As a normal part of the process of stopping the CMI service, open threads are closed (killed). This alarm
indicates that a timeout has occurred which means that the shutdown process is taking longer than
expected, causing the operating system to return an error.
History
Cisco Unified Communications
Release
8.0(1)
Cisco Unified Serviceability Alarm Definition Catalog
CMIAlarmCatalog/CMI
Severity
WARNING
Routing List
Event Log
SDI
OL-22523-01
Action
Name changed from kThreadKillingError.
Enum Definitions for MediaResourceType is updated.
Cisco Unified Communications Manager Managed Services Guide
Warning-Level Alarms
6-291