Performance Monitoring in RTMT
Table 5-1
Setting
Frequency Pane
Trigger alert on every poll;
trigger up to...
Schedule Pane
24-hours daily; start/stop
Note
If you require an e-mail notifications, check the Enable E-mail box.
You can also use data sampling in RTMT. The perfmon counters that display in the RTMT Perfmon
Monitoring pane have green dots that represent samples of data over time. You can configure the number
of samples to collect and the number of data points to show in the chart.
parameters.
Table 5-2
Parameter
Absolute
Delta
Delta Percentage
Cisco Unified Communications Manager Managed Services Guide
5-4
Chapter 5
Cisco Unified Real-Time Monitoring Tool Tracing, PerfMon Counters, and Alerts
Counter Alert Configuration Parameters (continued)
Description
Click the radio button that applies.
Trigger alert on every poll—If you want the alert notification
to activate on every poll when the threshold is met, click this
radio button.
For example, if the calls in progress continue to go over or
under the threshold, the system does not send another alert
notification. When the threshold is normal (between 50 and
100 calls in progress), the system deactivates the alert
notification; however, if the threshold goes over or under the
threshold value again, the system reactivates alert notification.
Trigger up to...—If you want the alert notification to activate at
certain intervals, click this radio button and enter the number
of alerts that you want sent and the number of minutes within
which you want them sent.
Click the radio button that applies:
24-hours daily—If you want the alert to be triggered 24 hours
a day, click this radio button.
Start/Stop—If you want the alert notification activated within
a specific time frame, click the radio button and enter a start
time and a stop time. If the check box is checked, enter the start
and stop times of the daily task. For example, you can
configure the counter to be checked every day from 9:00 am to
5:00 pm or from 9:00 pm to 9:00 am.
Data Sample Parameters
Description
Because some counter values are accumulative, choose Absolute to
display the data at its current status.
Choose Delta to display the difference between the current counter
value and the previous counter value.
Choose Delta Percentage to display the counter performance
changes in percentage.
Table 5-2
lists and describes the
OL-22523-01