1360
C
77: MPLS TE C
HAPTER
Creating MPLS TE
Tunnel over Static
CR-LSP
Configuration
Prerequisites

Configuration Procedure

ONFIGURATION
Creating MPLS TE tunnels over static CR-LSPs does not involve configuration of
tunnel constraints or the issue of IGP TE extension or CSPF. What you need to do is
to create a static CR-LSP and a TE tunnel using static signaling and then associate
them.
Despite its ease of configuration, the application of MPLS TE tunnels over static
CR-LSPs is restricted because they do not accept bandwidth constraints and
cannot dynamically adapt to network changes.
Static CR-LSPs are special static LSPs. They share the same constraints and use the
same label space spanning 16 to 1023.
Before making the configuration, do the following:
Configure static routing or an IGP protocol to make sure that all LSRs are
reachable.
Configure MPLS basic capabilities.
Configure MPLS TE basic capabilities.
Follow these steps to create an MPLS TE tunnel over a CR-LSP:
To do...
Enter system view
Enter the interface view of an MPLS
TE tunnel
Configure the tunnel to use static
CR-LSP
Submit the current tunnel
configuration
Exit to system view
Use the command...
system-view
interface tunnel
tunnel-number
mpls te signal-protocol
static
mpls te commit
quit
Remarks
--
--
Required
Required
--