1072
C
65: IP
6 RIP
HAPTER
V
Configuration
Prerequisites
Configuration Procedure
Configuring RIPng
Advanced Functions
Configuring an
Additional Routing
Metric
C
NG
ONFIGURATION
You need to enable RIPng first before configuring other tasks, but it is not
necessary for RIPng related interface configurations, such as assigning an IPv6
address.
Before the configuration, accomplish the following tasks first:
Enable IPv6 packet forwarding.
■
Configure an IP address for each interface, and make sure all nodes are
■
reachable.
Follow these steps to configure the basic RIPng functions:
To do...
Enter system view
Create a RIPng process and
enter RIPng view
Return to system view
Enter interface view
Enable RIPng on the interface ripng process-id enable
n
If RIPng is not enabled on an interface, the interface will not send and receive any
RIPng route.
This section covers the following topics:
Configuring an Additional Routing Metric
■
Configuring RIPng Route Summarization
■
Advertising a Default Route
■
Configuring a RIPng Route Filtering Policy
■
Configuring a RIPng Priority
■
Configuring RIPng Route Redistribution
■
Before the configuration, accomplish the following tasks first:
Configure an IPv6 address on each interface, and make sure all nodes are
■
reachable.
Configure RIPng basic functions
■
Define an IPv6 ACL before using it for route filtering. Refer to
■
ACLs" on page 1881
Define an IPv6 address prefix list before using it for route filtering. Refer to
■
"Routing Policy Configuration" on page 991
An additional routing metric can be added to the metric of an inbound or
outbound RIP route, namely, the inbound and outbound additional metric.
Use the command...
system-view
ripng [ process-id ]
quit
interface interface-type
interface-number
for related information.
Remarks
--
Required
Not created by default
-
--
Required
Disabled by default
"Configuring
for related information.
Need help?