Interval Errors Box
The
box provides T1 line statistics in the following
Interval Errors
categories:
Interval Number
appear in this box. This column displays a number from 1 to 96,
, or
Current
Out of Frame Errors
events that occurred. An OOF event begins when the network
interface sends two of four incorrect consecutive frame
synchronizing bits, and ends when reframe occurs.
BiPolar Violations
errors. For AMI-coded signals, a BPV event occurs when there
are two consecutive pulses of the same polarity. For B8ZS-
coded signals, a BPV event occurs when there are two
consecutive pulses of the same polarity that are not part of the
zero substitution code.
CRC Errors
when the CRC field calculated by the installation, based on the
incoming DS1 signal, does not agree with the CRC field
contained in the DS1 signal received from the network.
Controlled Slip
or deletes a DS1 frame.
Path Code Violations
occur on the remote side of a Layer 1 connection.
Line Code Violations
occur on the local side. A Layer 1 connection does not need to
be established.
Managing Remote Access Concentrators Using Annex Manager
lists each 15-minute interval for which statistics
.
Total
lists the number of Out of Frame (OOF)
lists the number of BiPolar Violation (BPV)
lists the number of CRC errors. A CRC error occurs
lists the number of times the T1 engine replicates
lists the number of coding violations that
lists the number of coding violations that
Chapter 3