Bay Networks 5399 Manual page 275

Remote access concentrators using annex manager
Hide thumbs Also See for 5399:
Table of Contents

Advertisement

ps_history_buffer
redisplay_line
remote_address
reset_idle_time_on
is used with the
Telnet
port keeps in a buffer. Incoming data is buffered continuously before, during,
and after the Telnet session. Reset the port after changing this parameter value.
Type
Async
Values
0 to 32767
Default
0
Lists
Async Ports, Basic Async Port
defines the reprint line character for CLI users.
Type
Async
Values
+ any character
Ctrl
Default
+
Ctrl
R
Lists
Async Port, Command_Line_Editing
contains the IP address for a host at the other end of the serial line. This parameter
works only when the mode parameter is set to
Type
Async
Values
IP address
Default
0.0.0.0
Lists
Async Port, PPP, SLIP
defines whether input or output resets the idle timer. The idle time is the time
lapse between activity and inactivity at the device. This parameter works with
the
command.
who
Type
Async
Values
input or output
Default
input
Lists
Async Port, Idle Timer
Managing Remote Access Concentrators Using Annex Manager
command to indicate how much incoming data a slave
(displays as ^R)
Appendix A
RAC Parameters
,
or
.
autodetect
slip
ppp
A-85