Bay Networks 5399 Manual page 287

Remote access concentrators using annex manager
Hide thumbs Also See for 5399:
Table of Contents

Advertisement

t1_info
tcp_keepalive
tdi_distance
tdi_framing
contains information about the T1 line supplied by the telephone company.
Type
T1 DS1
Values
0 to 16 characters
Default
n/a
Lists
DS1 Line, T1_DS1
specifies the length of time a TCP connection must be idle before a RAC sends
keep-alive messages. A keep-alive message contains no data, but solicits an
acknowledgment from the other end of a connection to determine whether the
connection is still active. If the recipient does not acknowledge the message after
eight retries, the RAC drops the connection. You can use
default value) to set the keep-alive time to 120 minutes, or you can enter
disable the keep-alive mechanism. The
parameters override values in this parameter for those individual ports.
Type
RAC
Values
0 to 255 minutes
Default
0 minutes
Lists
RAC Only, Basic RAC
indicates the length of the cable that runs between the equipment and the Drop
and Insert Interface.
Type
T1 DS1
Values
1 to 655 feet
Default
1 foot
Lists
DS1 Line, T1_DS1
selects the superframe format used on the T1 Drop and Insert Interface. If there
is terminal equipment on this interface, your selection must match the format of
the terminal equipment.
Type
T1 DS1
Values
esf, d4
Default
esf
Lists
DS1 Line, T1_DS1
Managing Remote Access Concentrators Using Annex Manager
Appendix A
(the Annex Manager
0
and
port_tcp_keepalive
printer_tcp_keepalive
RAC Parameters
to
255
A-97