Bay Networks 5399 Manual page 207

Remote access concentrators using annex manager
Hide thumbs Also See for 5399:
Table of Contents

Advertisement

CallDef_forwarding_
timer
CallDef_hardware_tabs
CallDef_Imask_7bits
sets the amount of time in ten millisecond intervals that can elapse before a RAC
or an ISDN Primary Rate RAC forwards received data. If new data arrives before
the timer expires, the RAC resets the timer. If you enter
is the Annex Manager default value.
Setting
CallDef_forwarding_count
have a severe effect on the network when heavy serial input occurs.
Type
RAC
Values
0 to 255 tens of milliseconds
Default
5 (50 milliseconds)
Lists
RAC Only, Call Defaults, Idle Timer
allows a RAC or an ISDN Primary Rate RAC to convert ASCII tab characters
to the correct number of spaces when a terminal does not support hardware tabs.
This parameter works only for CLI sessions.
Type
RAC
Values
enabled or disabled
Default
enabled
Lists
RAC Only, Call Defaults, Cmd Line Editing
allows a RAC or an ISDN Primary Rate RAC to mask input to seven bits. If you
choose
, the RAC expects eight-bit ASCII input.
disabled
Type
RAC
Values
enabled or disabled
Default
disabled
Lists
RAC Only, Basic Async Port, Call Defaults
Managing Remote Access Concentrators Using Annex Manager
Appendix A
RAC Parameters
, the RAC uses
0
to
or
1
CallDef_forwarding_timer
, which
5
to
can
0
A-17