Tektronix DG2030 User Manual page 173

Data generator
Hide thumbs Also See for DG2030:
Table of Contents

Advertisement

Setup Menu
Single
3 76
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Line No.
Block
Repeat Count
0
BK0
1
BK1
2
BK2
Line No.
0
1
Sequence
BK0
BK1
BK1 BK1
Output
Sequence
Figure 3 57: Repeat Mode pattern data output (when a sequence is defined)
Pattern data is output only once when a trigger input is received. A trigger signal
is received either when the front panel FORCE TRIGGER button is pressed or
when an external trigger signal is input to the TRIGGER INPUT connector.
When no sequence is defined, all of the pattern data is output as a single
waveform as shown in Figure 3-58. If a sequence is defined, the sequence
ordering and repeat (Repeat Count) functions are applied as shown in Figure
3-59. The extended sequence functions (trigger input, event jump, etc.) are
ignored.
Pattern Data Output
Pattern Data
Trigger Input
Figure 3 58: Single Mode pattern data output (when no sequence is defined)
BK0
1
3
Pattern Data
2
2
0
BK2
BK2
BK0
BK1
BK1
BK2
1
2
BK1
BK1 BK2
BK2
DG2030 User Manual