Tektronix DG2030 User Manual
Tektronix DG2030 User Manual

Tektronix DG2030 User Manual

Data generator
Hide thumbs Also See for DG2030:
Table of Contents

Advertisement

Quick Links

sales@artisantg.com
artisantg.com
(217) 352-9330 |
|
Click HERE
Find the Tektronix DG2030 at our website:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DG2030 and is the answer not in the manual?

Questions and answers

Summary of Contents for Tektronix DG2030

  • Page 1 (217) 352-9330 | Click HERE Find the Tektronix DG2030 at our website:...
  • Page 2 User Manual DG2030 Data Generator 071-0059-50 This document applies to firmware version 1.00 and above. www.tektronix.com Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 3 Copyright © Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supercedes that in all previously published material. Specifications and price change privileges reserved. Tektronix, Inc., P.O. Box 500, Beaverton, OR 97077 TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
  • Page 4 Tektronix, with shipping charges prepaid. Tektronix shall pay for the return of the product to Customer if the shipment is to a location within the country in which the Tektronix service center is located.
  • Page 5 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 6: Table Of Contents

    ........2-49 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 7 ..........3-55 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 8 ..........3-86 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 9 ......... Index DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 10 ......2-47 Figure 2-29: DG2030 and oscilloscope connection ....
  • Page 11 ........3-39 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 12 ........3-99 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 13 ......viii DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 14 ......Table 2-1: DG2030 display elements ......
  • Page 15 ........DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 16: General Safety Summary

    Keep Product Surfaces Clean and Dry. Provide Proper Ventilation. Refer to the manual’s installation instructions for details on installing the product so it has proper ventilation. DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 17 Symbols on the Product. The following symbols may appear on the product: WARNING Protective Ground CAUTION Double High Voltage (Earth) Terminal Refer to Manual Insulated DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 18: Service Safety Summary

    X Radiation. To avoid x-radiation exposure, do not modify or otherwise alter the high-voltage circuitry or the CRT enclosure. X-ray emissions generated within this product have been sufficiently shielded. xiii DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 19 Service Safety Summary DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 20: Preface

    This section also provides basic signal editing examples. Reference describes in detail the functions and use of the DG2030 main menus. Appendices describe product specifications, performance verification instruc- tions, and other information.
  • Page 21 Operation 2 Operation 3 Operation 4 Operation 5 Operation 6 (for example, 'Use the general purpose knob to set cursor field to 128.') Operation 7 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 22 6:00 a.m. - 5:00 p.m. Pacific time This phone number is toll free in North America. After office hours, please leave a voice mail message. Outside North America, contact a Tektronix sales office or distributor; see the Tektronix web site for a list of offices. xvii DG2030 User Manual Artisan Technology Group - Quality Instrumentation ...
  • Page 23 Preface xviii DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 24: Getting Started

    Product Description The DG2030 is a portable digital data generator designed for high performance and ease of use. The DG2030 is easy to use for testing and evaluating semicon- ductors and logic circuits, which are continually becoming faster and more complex.
  • Page 25: Initial Inspection

    H Logic function test systems can be constructed by combining this instrument with a logic analyzer. H Margin tests can be performed by using the DG2030 to generate patterns that have a low probability of occurrence or are difficult to generate.
  • Page 26: Options

    Option 01 (8 Channel This option adds 4 output ports for a total of 8 channels. Contact your Tektronix Output) sales representative if you intend to add this option to a DG2030 that you are already using. Option 1R (Rack Mount) When option 1R is specified, the DG2030 is shipped configured for mounting in a 19-inch rack.
  • Page 27: Power Cord Options

    Getting Started Power Cord Options Table 1-1 lists the power cords available with the DG2030. Table 1 1: Power cord options Option Description Part number Europe, 220 V/6A 161 0104 06 United Kingdom, 240 V/6A 161 0104 07 Australia, 240 V/6A...
  • Page 28: Table 1-3: Optional Accessories

    Used to provide the flexible connection for output signal and grounding by attaching to the pin header end of the 50 W cable (SMB to pin header or pin header to pin header). DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 29: Installation

    To properly install and power on the instrument, perform the following steps: 1. Check that the operating environment is correct. The DG2030 operates correctly in ambient temperatures from +10_ C to +40_ C and relative humidity from 20% to 80%. If the instrument is stored at temperatures outside this usage temperature range, do not switch on the power until the chassis has come within the operating temperature range.
  • Page 30 CAUTION. The DG2030 is shipped with a power cord appropriate for use with normal 115 V power systems. If the DG2030 is to be used with 230 V power, the power cord must be replaced with one appropriate for the power source used.
  • Page 31: Table 1-4: Power Cord Identification

    North America 230 V Switzerland 230 V North American 115 V/15A Plug NEMA 5 20P North American 120/208 V 3 Phase Plug NEMA L21 30P DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 32: Standby Power

    NOTE. the instrument needs to be warmed up for at least 20 minutes and then be calibrated for the clock in order to operate at its optimum precision. DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 33: Start-Up Diagnostics

    If this happens, turn off the instrument, wait until the chassis temperature is within normal operating range, and then switch the power on again. NOTE. Contact your local Tektronix Field Office or representative if an error is displayed. 1 10 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ...
  • Page 34: Power Off

    Getting Started Power Off To power off the DG2030, press the ON/STBY switch. 1 11 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 35 Getting Started 1 12 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 36: Operating Basics

    This section also describes the terminology and content of representative screen displays. Front Panel Figure 2-1 shows the layout of the DG2030 front panel. Figure 2-2 describes each front-panel control in detail. DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 37: Figure 2-1: Front Panel Overview

    Figure 2 1: Front panel overview DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 38: Figure 2-2: Front Panel Controls

    Applying external signal pressed, the input value and unit are confirmed. cursor during character input. voltages can damage the instrument. Figure 2 2: Front panel controls DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 39: Figure 2-3: Rear Panel Connectors

    Figure 2 3: Rear panel connectors DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 40: Figure 2-4: Floppy Disk Drive

    Floppy Disk Drive Figure 2-4 shows the floppy disk drive controls and indicators. The floppy disk drive is located on the right side of the DG2030 chassis. You use the floppy disk drive to save and recall instrument pattern and setting data.
  • Page 41: Figure 2-5: Display Elements

    Also shown are a popup menu and message box. Table 2-1 describes each element in detail. Figure 2 5: Display elements DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 42: Table 2-1: Dg2030 Display Elements

    Operating Basics Table 2 1: DG2030 display elements Figure number Label Description Page Status area Displays the current status of the instrument. This status line is always displayed, whichever menu is displayed. The status line displays the following four items.
  • Page 43: Theory Of Operation

    Operating Basics Theory of Operation This section presents an overview of the DG2030 hardware, data structures, and operating modes to allow you to take full advantage of the DG2030. Block Diagram Figure 2-6 shows the main hardware blocks that make up the instrument. This section describes these hardware blocks to provide the background knowledge necessary to use the instrument effectively.
  • Page 44 The output channels level-convert the pattern signals from the pattern generation unit to output signals appropriate for the device under test. They also handle fine adjustment of specific bit timing. DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 45: Data Structure Overview

    Data Structure Overview To make full and efficient use of the DG2030, you need to understand the DG2030 data structures. This section presents an overview of the pattern data, setup data, and sequence data. Figure 2-8 shows the DG2030 data structures that are described in the following sections.
  • Page 46: Figure 2-8: Data Structures

    Definition of the correspondence relation ship between pattern data and output bits Setup data Settings for the above items Sequence data Pattern output sequence program 2 11 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 47 Block delimiters are set in word units. Sequences, which are described later, control data output in block units. 2 12 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 48: Operating Modes Overview

    Run Modes In the run modes, pattern output is controlled by the pattern generation unit’s pattern control circuit. The DG2030 supports four run modes: repeat, single, step, and enhanced. These run modes are specified with the SETUP → Run Mode menu. Table 2-3 provides functional information for each mode.
  • Page 49: Table 2-4: Update Modes

    In such cases, it is more efficient to perform a number of edit operations and then update the output data in manual mode. 2 14 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 50: Basic Menu Operation

    Pressing one of the menu buttons at the center of the instrument’s front panel displays one of the menus that forms the basis of DG2030 operation. There are four menu buttons, EDIT, SETUP, APPLICATION, and UTILITY, as shown in Figure 2-9.
  • Page 51: Menu Notation

    3. Press the Control Condition side button. 4. Press the Change Inhibit Control side button. 5. Select Both from the popup menu. 6. Press the OK side button. 2 16 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 52: Menu Item Display

    Menu items that cannot numeric values to be set be used in the current using the numeric keys or instrument state the general purpose knob 2 17 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 53: Numeric Input

    Units ENTER Keys Buttons Figure 2 10: DG2030 front panel keypad Using the Keypad Use the following procedure to input numeric values with the numeric keys, ENTER key, and units buttons on the front panel. 1. Press the button for the menu item to be changed.
  • Page 54: Figure 2-11: Numeric Entry In A Menu Item Field

    If a value outside the allowable range of a parameter is set, the value will be replaced with the largest or smallest value allowable for that parameter. 2 19 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 55: Figure 2-12: General Purpose Knob And Arrow Buttons

    You do not need to use the front panel ENTER key to confirm a value when using the general purpose knob to change a value. The input value is confirmed automatically without pressing the ENTER key. 2 20 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 56: Pattern Data Display Format

    Use the EDIT ! Settings item to select the display format. Figures 2-14 through 2-16 show the three display formats. Figure 2 14: Timing display format 2 21 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 57: Figure 2-15: Table Display Format

    If no groups are defined, data can only be displayed in binary format. 2 22 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 58: Edit Operations

    Another problem is that the screen area is not large enough to make selections from the editing operations menu items while checking the data being edited on the screen. The DG2030’s user interface was designed with these points in mind. The DG2030 pattern data editing functions separates the selection and execution of editing operations.
  • Page 59: Area And Point Cursors

    Each type of cursor has a different form. They are called the area cursor and the point cursor. Figure 2-18 shows these cursors. 2 24 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 60: Figure 2-18: Area And Point Cursors

    Cursor window with the front panel CURSOR button. 2 25 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 61: Text Input

    Press Cancel to cancel the operation and return to the state prior to selecting the current menu. Figure 2 20: Popup message box 2 26 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 62: Menu Trees

    Move to next block Move to previous block Move to block(any) Add block delimiter here Delete current block delimiter Rename current block Resize current block 2 27 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 63 Make Sequence Insert Event Jump Delete Jump to Repeat Count Set Enhanced Control Repeat Special Delete All Make Simple Sequence Edit Sub Sequence 2 28 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 64 Repeat Run Mode Single Step Enhanced Update Trigger Slope Trigger Level Impedance Source State Interval Time Source Clock Int FREQ Ext FREQ 2 29 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 65 Data Bits Parity Stop Bits Handshake Power up Pause Date/Time Reset to Factory Security Immediate De skew Reset Skew Status Type Diag Execute 2 30 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 66: Operating Examples

    NOTE. These examples do not cover all the features and functions of the DG2030. They are intended only to introduce the operations required to execute the instrument’s basic functions. Required Equipment The following equipment is required for examples 1 through 4.
  • Page 67: Before Starting Examples

    Before Starting Examples Be sure that the DG2030 is properly installed. Refer to Installation on page 1-6. Turn the DG2030 on. Refer to Power On on page 1-9 for details on turning the DG2030 on. You do not need to connect the oscilloscope until Example 3.
  • Page 68: Example 1: Creating A Pattern And Storing Into A File

    Bottom button Popup menu Side button Settings Set memory 1024 * size ENTER * Use the front panel keypad to enter numeric values. 2 33 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 69 Side button button Execute Binary up Action counter ENTER EXECUTE This creates the binary pattern shown in Figure 2-22 in DATA0 to DATA3. 2 34 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 70: Figure 2-22: Binary Pattern Creation

    Press the EXECUTE button to insert the character in the file name. The data in this procedure is saved in the file COUNT1.PDA. 2 35 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 71: Example 2: Loading And Editing A Pattern Stored In A File

    Setup Select the file COUNT1.PDA from the file list using the general purpose knob. This loads the pattern created in example 1. 2 36 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 72 Popup Menu Side Button Execute Set scope Action Set the block cursor to cover DATA5 using the up and down arrow buttons. 2 37 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 73 This step inserted glitches at the points for cursor positions 32 and 96. Figure 2-23 shows the pattern edited in example 2. 2 38 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 74: Figure 2 23: Pattern Edited In Example 2

    Side Button File Save Data & Setup Clear String COUNT2 The data in this procedure will be saved in the file COUNT2.PDA. 2 39 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 75: Example 3: Signal Output

    NOTE. The MSB setting may change depending on the direction the general purpose knob is turned. If that happens, the MSB setting must be set again. 2 40 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 76 Menu button Bottom button Popup menu Side button button Rename Clear String Then you can see a display as shown in 2-24. 2 41 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 77: Figure 2-24: Group Data

    Condition Select CH0 from the list displayed in the screen using the knob on the front panel. Change Inhibit Control Select OFF 2 42 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 78 NOTE. Press the OK button when done to activate the allocations. Note that the allocations will not become valid unless the OK button is pressed. 2 43 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 79: Figure 2-25: Output Assign List And Channel Assignment

    Output Impedance Control. If the data is not assigned, `- - -' is displayed in this field. Figure 2 26: Output channel data bit allocation 2 44 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 80 Select channel CH0 by pressing the front panel up and down arrow buttons. High ENTER ENTER Set the output levels for channels CH1 to CH7 in the same manner. 2 45 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 81: Figure 2-27: Rise /Fall Time Settings

    As a slope, FAST or a value from the range can be selected. Figure 2 27: Rise /fall time settings 2 46 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 82: Figure 2-28: Output Parameter Settings

    Set the delays for channels CH5 to CH7 in the same manner. Delay Time Setting Output Voltage Level Settings Rise/Fall Time Settings Figure 2 28: Output parameter settings 2 47 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 83: Figure 2-29: Dg2030 And Oscilloscope Connection

    2-29. DG2030 Oscilloscope Two BNC Cables Figure 2 29: DG2030 and oscilloscope connection 10. Press the START/STOP button on the front panel. 11. Set up the oscilloscope appropriately and observe the pattern signals on the oscilloscope screen. Saving State of the 12.
  • Page 84: Example 4: Creating A Sequence

    H Block 2: Data pattern consisting of all zeros H Block 3: Binary down-counter pattern H Block 4: Data pattern consisting of all ones 2 49 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 85 4. Divide the data between block 1 (point 0 to 127) and block 2 (point 128 to 511). Use BK2 as the name for block 2. 2 50 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 86: Figure 2-31: Block Separation

    CURSOR button. Front panel Menu button Bottom button Popup menu Side button button ENTER Block Add block delimiter here Clear String 2 51 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 87 0. Then perform the following operations. Front panel Menu button Bottom button Popup menu Side button button Execute Binary up Action counter ENTER EXECUTE 2 52 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 88: Figure 2-32: Creating A Binary Up-Counter For Block Bk1

    CURSOR button. Front panel button Menu button Bottom button Popup menu Side button ENTER Execute Binary down Action counter ENTER EXECUTE 2 53 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 89 CURSOR button. Front panel Menu button Bottom button Popup menu Side button button ENTER Execute Set data to EXECUTE Action High 2 54 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 90 The BLOCK column of the lines defined with subsequences becomes highlight gray to distinguish from those defined with blocks, as shown in Figure 2-35. 2 55 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 91 11. Open the Make Sub-sequence popup menu. Front panel Menu button Bottom button Popup menu Side button button Make Special Sequence Edit Sub Sequence 2 56 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 92 20 for the BK4. Clear String SUB1 Go Back Go Back Line Pointer Figure 2 36: Line pointer 2 57 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 93 With the front panel down arrow button, advance the line pointer to the next line. Using above procedures, insert BK4 into the line 3. 2 58 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 94 Note that when the run mode is set to Enhanced, the displayed settings in the ENHANCED columns of the Make Sequence menu become gray. See Figure 2-37. 2 59 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 95 Operating Examples 18. Output the sequence and observe the pattern using an oscilloscope. See Figure 2-29 on page 2-48 for the connection between the DG2030 and the oscilloscope. Press START/STOP button on the front panel to start output. The message Waiting for Trigger is displayed soon at upper right part of the screen.
  • Page 96 Press OK once more if that message is displayed. 2 61 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 97 Operating Examples 2 62 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 98: Reference

    H Procedures for setting and saving instrument settings. NOTE. The current firmware version does not provide any functions under the APPLICATION menu. DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 99: Operation Outlines

    As well as pattern data, the setup information is also stored in the file. When you recall stored data from a file, the DG2030 will also be set up. You can prepare various data pattern to be used for inspecting facilities and/or checking in production lines.
  • Page 100: Creating Pattern Data And Sequences

    Create the next block pattern using the procedures described in Pattern Data above. Repeat step c through e until all blocks you need are created. DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 101: Advanced Control For Sequence

    3. Set the event and/or inhibit parameters with SETUP ! Output Condition ! Control Condition. 4. Set the run mode with SETUP ! Run Mode. DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 102: Edit Menu

    Combining blocks 3 27 Rename current block Changing a block name 3 28 Resize current block Changing the size of a block 3 28 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 103 Logical operations between pattern data items 3 48 Bit Operation Moving or copying pattern data 3 50 Serial Code Converter Serial code data conversion 3 51 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 104: Edit Display

    This section describes the EDIT menu screen shown in Figure 3-3. Table 3-2 provides a description and page number references. Figure 3 3: EDIT menu (timing display) DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 105: Table 3-2: Edit Menu Display

    (bright). Displays the width of the area cursor as a number of points and as a time. DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 106: File Menu

    The DG2030 can read data created and stored from the DG2020. The DG2030 will use the pattern data in the lower 8 bits. Also, the DG2030 can read DG2020 setup information except for those settings that are not common to both platforms.
  • Page 107: Import

    H Tektronix TLS series group data (file extension: .GRP) H Tektronix AWG2000 series waveform data (file extension: .WFM) H Tektronix DG2020 and DG2030 waveform data (file extension: .PDA) H CSV format data (file extension: .CSV). A procedure for formatting data in a CSV format is on page 3-14.
  • Page 108: Table 3-3: Import Parameters

    RP binary data from the Tektronix TDS and TLS series products are read in as RI data. The data cannot be converted to binary data if it is left in the RP state.
  • Page 109 With Marker Data Sets whether or not marker data is read, in addition to waveform data, for Tektronix AWG2000 series waveform file format data. Figures 3-5 and 3-6 show the data write operations in terms of point positions and data bit positions when pattern memory is the write destination.
  • Page 110 (AWG2000 Series Waveform Data) Pattern Memory Data Write MSB Setting (Dest MSB) Figure 3 6: Data write in terms of data bit positions 3 13 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 111 Edit Menu CSV Data Format The DG2030 can import vector data from the built-in floppy drive using a simple ASCII Comma Separated Variable (CSV) format. This section defines how the data is formatted for importing into the DG2030. The CSV format is defined as follows: Á...
  • Page 112 After all operating parameters have been set, the entire pattern can be stored on a floppy for non-volatile storage. The entire pattern will fit on one floppy since the DG2030 uses an instrument specific binary format that is more compact than ASCII format.
  • Page 113: Csv Data Format

    Export Writes pattern data to mass memory (floppy disk). Data is written either as CSV data or as Tektronix AWG2000 Series waveform data. The write method is specified by setting a parameter in a popup menu. NOTE. Icon data and hardware setup data are not saved in the output AWG2000 Series waveform data.
  • Page 114: Table 3-4: Export Parameters

    14 bits, MARKER 1 and 2 and DATA00 to DATA11, is displayed. Use the arrow buttons to select the AWG2000 Series bit and use the general purpose knob to allocate the DG2030 bit. Allocate all bits to be written by repeating this operation.
  • Page 115: New

    Edit Menu Exporting Large Data. The DG2030 internal memory capacity can not export an 8-bit wide pattern data in CSV format that is larger than 32768 (32 k) words. For the data to write into a floppy disk, the pattern must be segmented into 32 k (32768 words) blocks and saved to separate floppy disks.
  • Page 116: Settings Menu

    The reference mark only specifies the origin of the delta display. It does not affect the pattern data definition itself. 3 19 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 117: Select Memory Size

    Operation. Set the memory size Bottom button Popup menu Side button Settings Set memory size Set the number of points. 3 20 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 118: Select Arrow Key Function

    Popup Menu. Use the general purpose knob to select one of the following actions from the displayed popup menu. Items that currently cannot be used are dimmed as shown in Figure 3-11. 3 21 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 119: Table 3-5: Arrow Button Functions

    1 point at a time. See the descriptions of the Execute Action display only) menu for the Rotate region left/right and Rotate region up/down items. 3 22 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 120: Table 3-6: Pattern Data Display Format

    Set view type to table Sets the pattern data display method to the table format. Hexadecimal editing is possible if groups are defined. 3 23 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 121 Sets the pattern data display method to the binary format. Show overview Displays the whole pattern data on allocated memory area. Editing can not be performed in this mode. 3 24 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 122: Block Menu

    Move to block (any) Moves the cursor to the start of a block selected from a list of blocks in a popup menu. 3 25 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 123: Add Block Delimiter Here

    90 Points or Over After Block 1 Block 2 Block 3 Division Set a Block Delimiter Figure 3 14: Dividing a block 3 26 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 124: Delete Current Block Delimiter

    Move the knob icon to the Cursor window in the upper left of the screen. Move the cursor to the block whose block delimiter is to be deleted. Block Select Delete current block delimiter. 3 27 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 125: Rename Current Block

    After Change a Block 1 Block 2 Block 3 Block Size 90 Points or Over Figure 3 16: Change a block size 3 28 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 126: Execute Action Menu

    The area of the pattern data that will be the object of the edit may consist of the range enclosed by the area cursor, and may consist of the area following the cursor, depending on the selected editing operation. 3 29 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 127 H Group/bit Input. The groups or bits to be included in the range are set using the Execute Action → Set scope item. Popup menu Bottom button Side button Execute Action Select Set scope. Determine the scope. 3 30 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 128: Set Scope

    3 31 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 129: Cut

    Cursor Before Execution After Execution Paste Buffer Data Figure 3 20: Paste - insert 3 32 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 130: Paste-Replace

    The cursor becomes the area cursor. All the data bits in the editing area are set to 0. Before Execution After Execution Editing Area Figure 3 23: Set data to low 3 33 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 131 The cursor becomes the area cursor. The data in the editing area is inverted, i.e. 0 becomes 1, and 1 becomes 0. Before Execution After Execution Editing Area Figure 3 26: Invert data 3 34 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 132 (i.e., table and binary), the reordering is performed in the point direction. Before Execution DATA2 DATA1 DATA0 Editing Area After Execution DATA2 DATA1 DATA0 Editing Area Figure 3 27: Mirror vertical 3 35 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 133: Magnify

    After selecting Numeric input from the Action Menu, step is set using the Points/Step popup window. A ’step’ is the number of points that are set for each number that is input. 3 36 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 134: Numeric Input

    Side button Front Panel button Executed Action Numeric input Set the Points/Step using the general purpose knob. EXECUTE Input data using numeric keys. 3 37 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 135: Shifting

    Edit Menu Shifting The DG2030 provides several methods for the shifting of data in timing, table, or binary display. Timing. In timing display you can shift data using any one of the following: H Shift left (add zero) H Shift right (add zero)
  • Page 136 If a shifting operation is selected when the Select arrow key function item is selected in the Settings menu, data can be shifted up or down with the arrow buttons. 3 39 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 137: Rotating

    Edit Menu Rotating The DG2030 provides several methods for rotating data in timing, hexadecimal, or binary display. Timing. In timing display you can rotate data using any one of the following: H Rotate left H Rotate right The cursor becomes the area cursor. The data inside the editing area is rotated one point to the left or right.
  • Page 138: Creating Standard Pattern Data

    Creates a Gray code counter data pattern. When this menu item is selected, the instrument asks for the Points/Step value. This value sets the number of data points per counter step. 3 41 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 139 Set the editing range in the group/bit direction. Execute Action Select from the following items. Binary up counter Binary down counter Johnson counter Graycode counter 3 42 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 140: Enhanced Action Menu

    Dest Bit : DATA0 Region : Entered Points DATA0 Size : 100 From : 0 Figure 3 37: Creating the clock pattern 3 43 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 141: Table 3-10: Parameter Items

    Dest Bit memory is filled with the pattern. When Entered is selected, the pattern is written to the area specified by the From and Size parameters. 3 44 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 142: Shift Register Generator

    Î Î Î Î Î Î Î Î Î Î Î Î Î Î Î Î Figure 3 39: Register value and tap setting example 3 45 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 143: Table 3-11: Shift Register Generator Parameters

    Size When Entered was selected in the Region side menu item, specifies the number of points into which the pattern is written. 3 46 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 144 Set the value of a bit in the register with the 0 and 1 numeric keys. Set the tap on/off state for a bit using the -" numeric key. 3 47 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 145: Logical Operation

    Figure 3 41: Logical AND Operation Example Popup Menu. Figure 3 42: Logical Operation popup menu Table 3-12 describes the parameter items. 3 48 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 146: Table 3-12: Logical Operation Parameters

    Region (Select All or Entered) Set the parameters in the popup menu. (Src 1 Bit, Src 2 Bit, Operation, Dest Bit, From, Size) 3 49 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 147: Bit Operation

    The Maximum 9999 points can be entered. Entering 0 causes to quit the popup menu. 3 50 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 148: Serial Code Converter

    Popup menu Side button Enhanced Action Serial Code Converter Figure 3 44: Serial Code Converter menu Table 3-14 describes the parameter items. 3 51 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 149: Table 3-14: Serial Code Converter Parameters

    The current position is then moved on by the width of the pattern in the CURRENT column. The process then repeats. 3 52 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 150: Table 3-15: Edit Code Table Parameters

    OUTPUT CODE When the whole template matches, the data specified in this column is written to the destination. 3 53 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 151: Table 3-16: Numeric Key Description

    0 or 1 near the center of the SOURCE CONDITION’s CURRENT field when the field is empty changes data from the start of that area to the cursor position. 3 54 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 152: Make Sequence Menu

    NOTE. Enhanced columns in Figure 3-46 does not become effective unless the run mode is not set to Enhanced. For enhanced mode, refer to Run Mode Menu on page 3-75. 3 55 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 153: Insert

    Move the cursor to the line where the step is to be inserted using the general purpose knob. Insert Select the block. 3 56 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 154: Delete

    When Count is selected, that block is repeated the number of times specified by the Repeat Count setting. When Infinite is selected, the block is repeated indefinitely. 3 57 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 155: Special

    Removes a subsequence. When the Remove is selected, the popup menu for subsequence selection list brings up. Select a subsequence to be removed. Clear Removes all existed subsequences. 3 58 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 156: Limitations On Using Subsequences

    This can result in insufficient memory errors. The DG2030 does not check for sequence memory availability errors. If you run a sequence and the DG2030 displays a memory error message, reduce the number of subsequence calls, number of repeat counts and/or number of lines in the subsequences.
  • Page 157: About Event Jump

    Then, when the end of the output of the block in a line for which the Event Jump item is set approaches, the DG2030 checks the state of that flip-flop, activates the event jump operation, and clears the flip-flop. Keep it in mind that,...
  • Page 158: Undo

    Reverses editing operations performed on the data. Immediately after the Undo function is used, executing Undo again executes the reversed editing operation. 3 61 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 159 Edit Menu 3 62 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 160: Setup Menu

    Selecting a trigger slope 3 79 Trigger Level Setting the trigger level 3 79 Impedance Setting the trigger input impedance 3 80 3 63 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 161: Setup Display

    This section describes the SETUP menu screen. Figure 3-50 shows the menu. Table 3-18 provides descriptions and page number references. Figure 3 50: SETUP menu display 3 64 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 162: Table 3-18: Setup Menu Display

    Shows the data bits and the group to which each data bit 3 66 belongs. Shows the output channel. The channels are labeled numbered 0 through 7. 3 65 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 163: Group Assign Menu

    Figure 3-52 shows an example of a bit structure assignment. 3 66 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 164: Add Group

    Operation. Delete a group Bottom button Popup menu Side button Group Assign Select the group to be deleted. Delete Group 3 67 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 165: Rename

    (see Figure 3-53). Use the general purpose knob to select data bits and the up and down arrow buttons to select output channels. 3 68 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 166 Select a data bit with the general purpose knob. Select the channel to be assigned using the up and down arrow buttons. Assign 3 69 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 167: Assign Condition

    Operation. Set the event input level Bottom button Popup menu Side button Output Condition Control Condition Event Level (Set the event level) 3 70 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 168: Table 3-19: Impedance State Contol Methods

    OFF or External. Figure 3-54 shows a schematic overview of the high-impedance control circuit. 3 71 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 169: Level Condition Menu

    0.25 V and 5 V. The displayed voltages are the voltages when the outputs are open. Operation. Set the output low level Bottom button Popup menu Side button Level Condition Low (the low level setting) 3 72 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 170: Z On Stop

    The range varies depending on the pulse amplitude. See Figure A-1 on page A-4 for the relationship between range and pulse amplitude and the value represented by FAST. 3 73 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 171: Rise

    Turn the knob to set a rise time. When you want to set the rise time to FAST enter 0 from the front panel keyboard. 3 74 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 172: Delay

    Figure 3-57. Pattern Data Output Pattern Data Pattern Data Figure 3 56: Repeat Mode pattern data output (when no sequence is defined) 3 75 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 173 3-59. The extended sequence functions (trigger input, event jump, etc.) are ignored. Pattern Data Output Pattern Data Trigger Input Figure 3 58: Single Mode pattern data output (when no sequence is defined) 3 76 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 174: Repeat

    Infinite. Figure 3-60 shows an example of an enhanced mode sequence. Also refer to the description of the EDIT menu Make Sequence menu on page 3-55. 3 77 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 175: Update

    Operation. Set the data update method Bottom button Popup menu Side button Run Mode Update (Select Auto or Manual) 3 78 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 176: Trigger Menu

    +5 V in 0.1 V steps. Operation. Set the trigger level Bottom button Popup menu Side button Trigger Level (Set the trigger level.) 3 79 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 177: Impedance

    Operation. Set the trigger interval to on or off, and trigger interval. Bottom button Popup menu Side button Trigger Interval State (Select On or Off) Time (Set the interval time) 3 80 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 178: Clock Menu

    Operation. Input an external clock frequency Bottom button Popup menu Side button Clock Ext FREQ (Set the frequency) 3 81 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 179: Pll

    Operation. Set up the PLL circuit Bottom button Popup menu Side button Clock PLL (Select On or Off) 3 82 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 180: Application Menu

    Application Menu There are no items in this menu in the current version of the firmware. 3 83 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 181 Application Menu 3 84 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 182: Utility Menu

    Selecting functional block or all block and 3 99 executing the diagnostic test. th di ti t t Display FPanel Clock Trig SMenu TPMenu Execute 3 85 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 183: Mass Memory Menu

    Copy Copies the selected file on the floppy disk, creating a new file. Delete Deletes the selected file from the floppy disk. 3 86 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 184 NOTE. When deleting a file, the instrument asks for confirmation. Select either OK or Cancel. Bottom button Popup menu Side button Mass Memory Copy or Delete Select the file to delete. Delete 3 87 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 185: Special

    PC9800 2HD J3100 2HD IBM PC 2DD PC9800 2DD The volume label DG2030 is automatically assigned to the floppy disk by the formatting operation. Catalog Order Specifies the order for display when listing a directory. Select the order from the following types:...
  • Page 186: Cal Menu

    H When you need data pattern output with high precision frequency. H When the ambient temperature is changed by about ±5_C since the previous clock calibration. 3 89 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 187: Display/Hardcopy Menu

    Date and time display Message Area Display Clearing the Menu message Hardcopy Menu Figure 3 63: Display/hardcopy menu 3 90 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 188: Display

    Utility Menu Display Sets the date and time display, adjusts the screen brightness, and sets the dimmer. The dimmer function automatically reduces the screen brightness if the DG2030 is left for 10 minutes without any controls being used. Base menu...
  • Page 189: Hardcopy

    Menu item Format Extension Windows BMP Epson Epson ESC P EPS mono Encapsulated Postscript Thinkjet HP Thinkjet TIFF TIFF 3 92 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 190: Clear Message Area

    Clears the message displayed in the message area. Operation. Remove message displays Bottom button Popup menu Side button Display/Hardcopy Clear Message Area 3 93 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 191: System Menu

    Side button System Select Remote Port with the up and down arrow buttons. Select the port with the left and right arrow buttons. 3 94 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 192: Gpib

    Utility Menu GPIB Sets the GPIB operating mode and address of the DG2030 for remote control or hardcopy. Base Menu Item Function Configure Sets the GPIB operating mode. Operating Mode Function Talk/Listen Normal remote control Talk Only Used for hard copy output.
  • Page 193: Serial

    Side button System Select Power up Pause with the up and down arrow buttons. Select On with the left and right arrow buttons. 3 96 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 194: Date/Time

    Erases the instrument’s internal memory data. At the same time, the instrument is reset to the factory settings state. Operation. Delete memory data Bottom button Popup menu Side button System Security Immediate 3 97 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 195: Skew Menu

    Operation. Reset the skew Bottom button Popup menu Side button De skew Select a output channel with up and down Reset Skew arrow buttons. 3 98 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 196: Status Display

    ”Pass” is displayed in the Status display area. If an error occurs, ”Fail” is displayed. An error code is displayed in the Comment display area if a diagnostic test fails. See Figure 3-67. NOTE. Contact your Tektronix sales representative if any errors occur. Figure 3 67: Diag menu 3 99 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ...
  • Page 197: Table 3-22: Error Code

    Utility Menu Table 3-22 lists the error codes, their meaning, and failure board for the error code. See the DG2030 Service Manual for detailed descriptions of the error codes. Table 3 22: Error Code Error code Description Failed component CPU diagnostics error...
  • Page 198: Appendix A: Specifications

    H Functionality. Functionality describes instrument capabilities. Items marked with asterisk (*) are tested in the Performance Verification (Appendix B). The certification and compliances for the DG2030 are also found at the end of this appendix. Warranted Characteristics This section describes the warranted characteristics of the DG2030. These can be divided into two categories: electrical characteristics and environmental characteristics.
  • Page 199 Minimum pulse width y 100 ns Sensitivity y 1.0 Vp p Inhibit input Minimum pulse width y 100 ns Sensitivity y 1.0 Vp p DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 200 Input frequency range from 48.0 to 63.0 Hz 90 127 V AC Input frequency range from 48.0 to 440.0 Hz Maximum power 300 W Maximum current DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 201 Appendix A: Specifications Maximum Minimum Fast Amplitude ( into 50 W ) Vp p Figure A 1: Range of rise/fall times DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 202 Jump to the specified block after the next block Event input Event output External clock input = 36 ns (typical) Clock output Figure A 2: Signal timing DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 203 9 A peak for less than 5 line cycles, at 25 _C, after product has been off for at least 30 s. Cooling clearance Top clearance 2.5 cm (1 inch) Side clearance 15 cm (6 inches) Rear clearance 7.5 cm (3 inches) DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 204: Typical Characteristics

    Appendix A: Specifications Typical Characteristics This section will describe the typical characteristics for the DG2030. These values represent typical or average performance and are not absolutely guaran- teed. Table A 3: Electrical characteristics (typical) Characteristics Description Data and clock out...
  • Page 205 StdDev Pk-Pk StdDev Pk-Pk Clock output 30 ps 200 ps 12 ps 60 ps CH0 output 100 ps 340 ps 20 ps 90 ps DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 206: Nominal Traits

    Appendix A: Specifications Nominal Traits This section describes the general characteristics of the DG2030. These are divided into two main categories: Table A-6 Electrical Characteristics and Table A-7 Mechanical Characteristics. Table A 6: Nominal traits electrical characteristics Characteristics Description Operation mode Repeat Pattern data is repeatedly output.
  • Page 207 CH0, CH1, CH2, CH3, CH4, CH5, CH6, and CH7 (Referenced to clock out) Delay time -5 ns to +18 ns Resolution 20 ps A 10 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 208 BNC at rear panel Pulse width 9 or 10 clocks. Refer to P in Figure A 2 on page A 5. Impedance 50 W (typical) A 11 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 209 Width 362 mm (14.3 inches) including handle Length 491 mm (19.25 inches) including front cover 576 mm (22.2 inches) with handle extended A 12 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 210: Certification And Compliances

    Appendix A: Specifications Certification and Compliances The certification and compliances for the DG2030 are listed in Table A-8. Table A 8: Certifications and compliances Category Standards or description EC Declaration of Conformity - Meets intent of Directive 89/336/EEC for Electromagnetic Compatibility. Compliance was...
  • Page 211 Installation Category II (as defined in IEC 61010-1, Annex J) Pollution Degree 2 (as defined in IEC 61010-1) Safety Class I (as defined in IEC 61010-1, Annex H) A 14 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 212: Appendix B: Performance Verification

    Appendix B: Performance Verification This section describes the operation tests for the DG2030 data generator, and the procedures for those tests. The operation tests can be divided into two categories. H Self Tests. The DG2030 incorporates a diagnostic system that performs comprehensive instrument testing.
  • Page 213: Before Running The Operation Tests

    File Loading The performance check disk provided with the DG2030 includes the files listed in Table B-1. The specified file must be loaded into the DG2030 for each operation test item. These files include pattern data and setup information. Table B 1: Performance check disk's file list...
  • Page 214 Precision: 7 digits or higher Digital multi-meter DC voltage range: ±10 V Tektronix DM2510 Precision: 0.01 V Performance check disk Tektronix part no. 063 2922 XX (provided with the DG2030) Oscilloscope Bandwidth: 1 GHz or higher Tektronix TDS784A Function generator...
  • Page 215: Test Procedure Notes

    Side Menu General Purpose Knob Front Panel Button Menu Button Bottom Menu Bottom Button Side Button Figure B 1: Operating buttons and menu layout DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 216: Self Tests

    Appendix B: Performance Verification Self Tests Execute the DG2030 self tests and confirm that no errors occurred. 1. Press the required buttons in the following order. Selecting All from the Type side button causes the instrument to run the self-test on all test items.
  • Page 217 A30 Clock board Trigger diagnostics / calibration error A30 Clock board Sequence memory error A50 PG&Output board Pattern memory diagnostics error A50 PG&Output board DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 218: Performance Tests

    Appendix B: Performance Verification Performance Tests The performance test for the DG2030 must be performed in the following order. H Internal clock frequency H External clock input H Sequence & digital output H Inhibit function H Output level, amplitude, rise time and fall time accuracies...
  • Page 219 Characteristics Confirmation Procedure. 1. Load the TP1CLK.PDA test pattern file from the performance check disk. When the file is loaded, the DG2030 clock frequency will be set to 400 MHz internally and the PLL circuit will be turned on. The following steps check the clock frequency accuracy with the PLL circuit on and the internal clock frequency set to 400 MHz.
  • Page 220 100.0 mHz (10.0 s) 97 mHz  103 mHz 14. Press the START/STOP button on the front panel to stop output (the button’s LED goes off). DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 221: External Clock Input

    Connections. Connect the clock output from the DG2030 front panel to the oscilloscope CH1 input with an BNC cable. Connect the function generator output to the DG2030 rear panel clock input with the other BNC cable. AFG2020 Front Panel BNC Cable: connect to the AUX INPUT: CLOCK connector on the DG2030 rear panel.
  • Page 222 3. Confirm that the clock pulse waveform can be observed on the oscilloscope. 4. Press the START/STOP button on the front panel to stop output (the button’s LED goes off). B 11 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 223: Sequence & Digital Output

    DG2030 rear panel event input with the other BNC cable. Next, using the BNC cables, connect the CH0 signal output from the DG2030 to the oscilloscope CH2 input, the event output from the DG2030 rear panel to the oscilloscope CH3 input, and the sync output from the DG2030 rear panel to the oscilloscope CH4 input.
  • Page 224 1. Load the TP3PG.PDA test pattern file from the performance check disk. The following steps check the pattern data output operation in Repeat run mode. 2. Press the following buttons to set the DG2030 run mode to Repeat. Front panel...
  • Page 225 SYNC OUT Figure B 6: Repeat mode timing chart The following steps check the pattern data output operation in Single run mode. 7. Press the following buttons to set the DG2030 run mode to Single. Front panel Menu button Bottom button...
  • Page 226 Appendix B: Performance Verification The following steps check the pattern data output operation in Step run mode. 12. Press the following buttons to set the DG2030 run mode to Step. Front panel Menu button Bottom button Pop up menu Side button...
  • Page 227 CLOCK OUT EVENT OUT SYNC OUT BLOCK 4 CLOCK OUT EVENT OUT SYNC OUT Figure B 7: Single and step mode timing chart B 16 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 228 Appendix B: Performance Verification The following steps check the digital pattern output, event output and sync output in Enhanced run mode. 17. Press the following buttons to set the DG2030 run mode to Enhanced. Front panel button Menu button Bottom button...
  • Page 229 Trigger event is generated in every 10 ms. Confirm that the block pattern (BLOCK 1) waits for the trigger event and then outputs. 22. Press the following buttons to set the DG2030 clock frequency to 409.6 MHz. Front panel...
  • Page 230 BLOCK 1 CLOCK OUT EVENT OUT SYNC OUT BLOCK 2 CLOCK OUT EVENT OUT SYNC OUT Figure B 8: Enhanced timing chart B 19 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 231 Appendix B: Performance Verification The following steps check that the DG2030 internal trigger source generates a 1 ms trigger event every 10 seconds. 25. Press the following buttons to set the DG2030 trigger interval to 1 ms. Front panel button...
  • Page 232 32. Confirm that there is a 1 ms trigger event every 10 seconds on the oscillo- scope channel 2 display. 33. Press the following buttons to set the DG2030 trigger interval to 10 ms. Front panel Menu button...
  • Page 233 Appendix B: Performance Verification The following steps check the external trigger signal. 40. Press the following buttons to set the DG2030 trigger source to Ext. Front panel Menu button Bottom button Pop up menu Side button button SETUP Trigger Source (Set to Ext) 41.
  • Page 234 BNC Cable: connect to the AUX OUTPUT: SYNC connector on the DG2030 rear panel. Figure B 9: Sequence & digital output connections #3 42. Press the following buttons to set the DG2030 trigger source to 50 W. Front panel Menu button...
  • Page 235 Trigger event can be recognized by observing the CH1 output signal from the DG2030 on oscilloscope CH1 input. 46. Press the following buttons to set the DG2030 trigger slope to Negative. Front panel button...
  • Page 236: Inhibit Function

    Connections. Connect the CH1 output from the DG2030 front panel to the inhibit input on the DG2030 rear panel using the BNC cable. Connect the DG2030 front panel CH2 output to the oscilloscope CH1 input. Connect the sync output from the DG2030 rear panel to the oscilloscope CH4 input.
  • Page 237 4. Change the BNC cable connection from the DG2030 front panel CH2 to the DG2030 CH3 connector, and then confirm the CH3 output waveform as was done in step 3.
  • Page 238 11. Confirm that the clock output voltage level is almost 0 V. 12. Disconnect the BNC cable from the inhibit input on the DG2030 rear panel. 13. Confirm that the pulses with 10 MHz of frequency, +3 V of high voltage level and –1 V of low voltage level are continuously output from the...
  • Page 239 BNC to dual banana adapter Performance check disk Connections. Connect the CH0 output from the DG2030 front panel to the digital multi–meter input using the BNC cable, precision 50 W termination and BNC to dual banana adapter as shown in Figure B-11.
  • Page 240 1. Load the TP7LVL.PDA test pattern file from the performance check disk. The following steps check the high voltage levels on all output channels. 2. Press the following buttons to set the DG2030 high and low voltage levels. Front panel...
  • Page 241 Appendix B: Performance Verification 4. Confirm the high voltage level as following procedures: a. Press the STEP/EVENT button on the DG2030 front panel once to output high voltage level. b. Set the high and low voltage levels to the values indicated in Table B-5, and confirm that the digital multi–meter reading for each high voltage...
  • Page 242 The following steps check the clock output amplitude accuracy. 6. Disconnect the BNC cable from both the digital multi–meter input and the DG2030. And then connect the clock output to the oscilloscope CH1 input as shown in Figure B-12. 7. Load the TP8PULSE.PDA test pattern file from the performance check disk.
  • Page 243 5.23 ns to 7.49 ns 5.74 ns 4.67 ns to 6.81 ns -1.50 V +3.50 V 8.00 ns 6.70 ns to 9.30 ns B 32 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 244: Delay Time Accuracy

    Equipment Required Oscilloscope Two BNC cables Performance check disk Connections. Connect the clock and CH0 outputs from the DG2030 front panel to the oscilloscope CH1 and CH2 inputs, respectively, using the BNC cables. See Figure B-13. B 33 DG2030 User Manual...
  • Page 245 1. Load the TP8PULSE.PDA test pattern file from the performance check disk. 2. Press the START/STOP button on the front panel so that the button LED indicator turns on. 3. Press the following buttons to set the DG2030 CH0 output delay time to –5.00 n. Front panel Menu button...
  • Page 246 –300 ps to +300 ps. 7. Press the START/STOP button on the front panel to stop data output (the button’s LED goes off). B 35 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 247 Appendix B: Performance Verification B 36 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 248: Appendix C: Miscellaneous

    125 kg (275 pounds). 2. If the instrument is being shipped to a Tektronix Service Center for repair or calibration, attach a tag to the instrument showing the following: the owner...
  • Page 249: Inspection And Cleaning Procedures

    Missing items or parts of items, bent pins, Replace damaged or missing items, frayed broken or frayed cables, and damaged cables, and defective modules connectors DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 250 Do not use abrasive cleaners. 3. Clean the monitor screen with a lint-free cloth dampened with either ethyl alcohol or, preferably, a gentle, general purpose detergent-and-water solution. DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 251: Factory Settings

    1.4 V Impedance 1 kW Source Interval ! State Interval ! Time 10.0 s Clock Source Int FREQ 100.00 MHz Ext FREQ 100.00 MHz DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 252 However, when Security Immediate item is selected in the UTILITY System menu, the above items are reset. H The following UTILITY items Remote Port GPIB operation mode and address Serial parameters Date/Time DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 253: Conversion Table Examples

    Data bits already written after converted Data bits that will be written Data bits about after converted being written Figure C 1: Conversion image example DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 254 Past Current Next P.OUT Output code Example Input Output H Converting NRZ data to NRZI. Past Current Next P.OUT Output code Example Input Output DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 255 H Converting NRZ data to FM. Two bit are generated for each input bit. Past Current Next P. OUT Output code 0 11 1 00 0 10 1 01 Example Input Output DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 256 H Output bit is always set to 1 when input bit changes from 1 to 0 or 0 to 1. Past Current Next P. OUT Output code Example Input Output DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 257 111110 0010 000001 0011 100001 0011 011110 Example Input 0010 0011 0001 0011 0000 Output 000001 111 100001 110 000000 011110 011111 C 10 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 258 C-2 Enhanced, 3-77 exterior, C-3 Enhanced Action Menu, 3-43 ENTER Key, 2-3 instrument cabinet, C-3 Event, 3-70 Cleaning, Inspection and cleaning procedures, C-2 Index-1 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 259 Move cursor to prev/next edge in selected group, IEEE STD 488 Connector, 2-4 3-22 Impedance, 3-80 Move cursor to prev/next index, 3-22 Import, 3-10 Index-2 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 260 PLL, 3-82 Set data to low, 3-33 Point cursor, 2-24 Set Enhanced Control, 3-57 Port, 3-92 Set memory size, 3-20 Power Connector, 2-4 Index-3 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 261 Warranted Characteristics, A-1 START/STOP Button, 2-3 Startup Diagnostivs, 1-10 Status Menu, 3-99 Step, 3-77 STEP/EVENT Button, 2-3 Z on Stop, 3-73 Stop Bits, 3-96 Index-4 DG2030 User Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...

This manual is also suitable for:

Dg2040

Table of Contents