Cli Configuration - Tripp Lite NGI-M08C4POE8-2 Owner's Manual

Sfp slots managed industrial ethernet poe+ switch
Table of Contents

Advertisement

PVLAN.
CVLAN
- Add the customer VLAN ID into the Circuit sub-option.
If the CVLAN is not defined, the system returns 0.
PORT
- Add the transmit port ID into the Circuit sub-option.
FRAME
- Add the frame ID into the Circuit sub-option.
SHELF
- Add the shelf ID into the Circuit sub-option.
SLOT
- Add the slot ID into the Circuit sub-option.
For Example:
HOSTNAME=L2SWITCH.
SVLAN=44.
CVLAN=32.
Circuit Form=
RD+%SPACE+Department+%SPACE+%HOSTNAME+%SPACE+%PORT+_+%SVLAN+.+%CVLAN
The circuit sub-option result is: RD Department L2SWITCH 1_44.32

6.4.2.1 CLI Configuration

Node
Command
enable
show dhcp-options
enable
configure terminal
configure
dhcp-options option82
(disable | enable)
configure
dhcp-options option82
circuit_id
configure
dhcp-options option82
remote_id
configure
dhcp-options option82
circuit_frame VALUE
configure
dhcp-options option82
circuit_shelf VALUE
configure
dhcp-options option82
circuit_slot VALUE
The frame ID is configured with the CLI command, "dhcp-options
option82 circuit_frame VALUE". Or GUI Circuit Frame.
The shelf ID is configured with the CLI command, "dhcp-options
option82 circuit_shelf VALUE". Or GUI Circuit Shelf.
The slot ID is configured with the CLI command, "dhcp-options
option82 circuit_slot VALUE". Or GUI Circuit Slot.
This command displays the DHCP options
configurations.
This command changes the node to configure node.
This command disables / enables the DHCP option
82on the Switch.
This command configures the information of the
circuit ID sub-option.
This command configures the information of the
remote ID sub-option.
This command configures the frame ID for the circuit
sub-option.
This command configures the shelf ID for the circuit
sub-option.
This command configures the slot ID for the circuit
sub-option.