0x0040
7 words
0x0050
12 words
0x0060
16 words
0x0070
3 words
0x0080
1 word
0x0081
1 word
0x0090
1 word
Port Information
0x0100 to
1 word
0x0109
Word 8 Hi byte = '\0'
Word 8 Lo byte = '\0'
Product Serial Number
Ex: Serial No=A000000000001
ASCII
Firmware Version="8648-000-1.4.1.S0"
Word 0 Hi byte = '8'
Word 0 Lo byte = '6'
Word 1 Hi byte = '4'
Word 1 Lo byte = '8'
Word 2 Hi byte = '-'
Word 2 Lo byte = '0'
Word 3 Hi byte = '0'
Word 3 Lo byte = '0'
Word 4 Hi byte = '-'
Word 4 Lo byte = '1'
Word 5 Hi byte = '.'
Word 5 Lo byte = '4'
Word 6 Hi byte = '.'
Word 6 Lo byte = '1'
Word 7 Hi byte = '.'
Word 7 Lo byte = 'S'
Word 8 Hi byte = '0'
Word 8 Lo byte = '\0'
ASCII
Firmware Release Date="Mon Sep 30 18:51:45 2013"
HEX
Ethernet MAC Address
Ex: MAC = 00-01-02-03-04-05
Word 0 Hi byte = 0 x 00
Word 0 Lo byte = 0 x 01
Word 1 Hi byte = 0 x 02
Word 1 Lo byte = 0 x 03
Word 2 Hi byte = 0 x 04
Word 2 Lo byte = 0 x 05
HEX
Power 1(PWR) Alarm, DIP switch 1 need ON
0x0000: no alarm
0x0001: input voltage <44V
0x0002: input voltage > 57V
0x0003: No PWR input
HEX
Power 2(RPS) Alarm, DIP switch 1 need ON
0x0000: no alarm
0x0001: input voltage <44V
0x0002: input voltage > 57V
0x0003: No RPS input
HEX
Fault LED Status
0x0000: No
0x0001: Yes
HEX
Port 1 to 10Link Status
0x0000: Link down
0x0001: 10M-Full-FC_ON (FC: Flow Control)
0x0002: 10M-Full-FC_OFF
0x0003: 10M-Half-FC_ON
0x0004: 10M-Half-FC_OFF
0x0005: 100M-Full-FC_ON
0x0006: 100M-Full-FC_OFF
0x0007: 100M-Half-FC_ON
0x0008: 100M-Half-FC_OFF