05/08
Mode
Element
Sub
element
08
Setting
Process
Fuser
Fuser roller
Mode
temperature during
printing
08
Setting
Process
Fuser
Fuser roller
Mode
temperature during
printing
08
Setting
Process
Fuser
Low temperature
Mode
waiting
e-STUDIO557/657/757/857
Item
Subitem
Code Sub-
Plain paper
2010
2028
Temperature setting
2030
Details
Default
Acceptable
code
value
value
1
Low temperature
Refer to
0~14
contents
Thick paper 3
12
0~14
0
Thick paper 3
Refer to
0~12
contents
2
RAM
Contents
M
0: 140°C 1: 145°C 2: 150°C 3: 155°C 4: 160°C 5:
165°C 6: 170°C 7: 175°C 8: 180°C 9: 185°C 10:
190°C 11: 195°C 12: 200°C 13: 205°C 14: 210°C
<Default value>
e-STUDIO557: 8
e-STUDIO657/757/857:12
M
0: 140°C 1: 145°C 2: 150°C 3: 155°C 4: 160°C 5:
165°C 6: 170°C 7: 175°C 8: 180°C 9: 185°C 10:
190°C 11: 195°C 12: 200°C 13: 205°C 14: 210°C
M
Sets the temperature at which low-temperature
warming-up control starts.
0: 130℃ 1: 135℃ 2: 140℃ 3: 145℃ 4: 150℃ 5:
155℃ 6: 160℃ 7: 165℃ 8: 170℃ 9: 175℃ 10:
180℃ 11: 185℃ 12: Disabled
<Default value>
e-STUDIO557: 5
e-STUDIO657:
JPC: 5
TWD: 6
Others: 7
e-STUDIO757/857:
JPC: 7
Others: 9
* The setting value of this code is applied when "0"
(disable) is set to the code 08-2226-5.