■ Procedure
1. Remove the Fixing Outer Delivery Unit Guide [1] from the Fixing Assembly [2].
• 1 Screw [3]
• 2 Claws [4]
NOTE:
When the consumable parts have been replaced, be sure to clear the parts counter shown below in service mode.
• COPIER > COUNTER > DRBL-1 > FX-UNIT
Removing the Fixing Delivery Upper Guide
■ Preparation
1. Remove the Fixing
Assembly."Removing the Fixing Assembly" on page 261
2. Remove the Fixing Outer Delivery Unit
1x
2x
[4]
Guide."Removing the Fixing Main Unit" on page 261
262
[2]
[1]
[3]
4. Disassembly/Assembly