Canon imageRUNNER ADVANCE 4551i Service Manual page 465

Hide thumbs Also See for imageRUNNER ADVANCE 4551i:
Table of Contents

Advertisement

614-0002-00
Detection Description
Remedy
614-0006-00
Detection Description
Remedy
614-0101-00
Detection Description
Remedy
Flash PCB error
The file system could not be initialized normally at startup.
When this error occurs, the system has not been started normally. Therefore, it may not be
recorded in the error log.
[Related parts] R1.00
- Flash PCB
- Main Controller PCB
[Remedy] Perform the following in the order while checking whether the error is cleared.
- Reinstall the necessary application software once the error is cleared.
1. After turning OFF the main power, remove and then install the Flash PCB again to check that
it is properly installed.
2. Enter safe mode using (2+8) startup, and execute Flash Format using SST or a USB flash drive.
3. After replacing the Flash PCB, reinstall the system software using SST or a USB flash drive.
4. Replace the Main Controller PCB.
[Reference] For backup and restoration, refer to "Adjustment> Main Controller System" and
"Appendix> Backup Data List" in the Service Manual.
Flash PCB error
Bootable was not found on the Flash PCB.
[Related parts] R1.00
- Flash PCB
- Main Controller PCB
[Remedy] Perform the following in the order while checking whether the error is cleared.
- Reinstall the necessary application software once the error is cleared.
1. After turning OFF the main power, remove and then install the Flash PCB again to check that
it is properly installed.
2. Enter safe mode using (2+8) startup, and execute Flash Format using SST or a USB flash drive.
3. After replacing the Flash PCB, reinstall the system software using SST or a USB flash drive.
4. Replace the Main Controller PCB.
[Reference] For backup and restoration, refer to "Adjustment> Main Controller System" and
"Appendix> Backup Data List" in the Service Manual.
Flash PCB error
An error was detected in the system area. (Initialization failed at startup or I/O error at startup)
When this error occurs, the system has not been started normally. Therefore, it may not be
recorded in the error log.
[Related parts] R1.00
- Flash PCB
- Main Controller PCB
[Remedy] Perform the following in the order while checking whether the error is cleared. Although
the error is cleared by "HD-CHECK", it may occur again. Thus, perform Remedies 1 to 4.
1. Check the related harness/cable and connector.
2. Select COPIER> FUNCTION> SYSTEM> CHK-TYPE> "0", and execute "HD-CHECK". Then,
turn OFF and then ON the main power.
3. Obtain the necessary backup data by referring to the backup data list.
[Reference] For backup and restoration, refer to "Adjustment> Main Controller System" and
"Appendix> Backup Data List" in the Service Manual.
4. Enter safe mode using (2+8) startup, and execute Flash Format using SST or a USB flash drive.
5. After replacing the Flash PCB, reinstall the system software using SST or a USB flash drive.
6. Replace the Main Controller PCB.