Advertisement

COPIER > COUNTER > DRBL-1
DV-UNT-K
1
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Default Value
Amount of Change per
Unit
C1-PU-RL
1
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Default Value
C1-SP-RL
1
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Default Value
C1-FD-RL
1
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Default Value
Developing Assembly parts counter
Developing Assembly
1st line: Total counter value from the previous replacement
2nd line: Estimated life
When checking the consumption level of parts/replacing the parts
To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and then press OK key.
Clear the counter value after replacement.
0 to 99999999
0
1
Cassette 1 Pickup Roller parts counter
Cassette 1 Pickup Roller
1st line: Total counter value from the previous replacement
2nd line: Estimated life
When checking the consumption level of parts/replacing the parts
To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and then press OK key.
Clear the counter value after replacement.
0 to 99999999
0
Cassette 1 Separation Roller parts cntr
Cassette 1 Separation Roller
1st line: Total counter value from the previous replacement
2nd line: Estimated life
When checking the consumption level of parts/replacing the parts
To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and then press OK key.
Clear the counter value after replacement.
0 to 99999999
0
Cassette 1 Feed Roller parts counter
Cassette 1 Feed Roller
1st line: Total counter value from the previous replacement
2nd line: Estimated life
When checking the consumption level of parts/replacing the parts
To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and then press OK key.
Clear the counter value after replacement.
0 to 99999999
0
830