COPIER > ADJUST > HV-TR
TR-TP-LV
1
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Unit
Default Value
Related Service Mode
Amount of Change per
Unit
TR-OFT1
2
Amount of Change per
Unit
TR-OFT2
2
Amount of Change per
Unit
TR-OFT3
2
Amount of Change per
Unit
TR-OFT4
2
Amount of Change per
Unit
TR-OFT5
2
Amount of Change per
Unit
TR-OFT6
2
Amount of Change per
Unit
TR-OFT7
2
Amount of Change per
Unit
TR-OFT8
2
Amount of Change per
Unit
TR-OFT9
2
Amount of Change per
Unit
Adj transfer lead edge weak bias level
This mode determines the level to apply voltage for transfer lead edge weak bias during the second
printing of 2-sided.
+: The output level increases.
-: The output level decreases.
When the fixing delivery delay jam occurs, decrease the output level.
This item is used when the fixing delivery delay jam (0107) of the 2nd side of 2-sided occurs in the
following condition.
- High temperature/high humidity environment
- The cassette heater is ON
- Use of the thin paper 1 and plain paper 1/2
Enter the setting value, and then press OK key.
When the transfer bias level (TR-TP-LV) is increased and the application time (TR-TP-TM) is too
shorter, the jam may occur easily.
When the transfer bias level (TR-TP-LV) is decreased and the application time (TR-TP-TM) is too
longer, the leading part of the image becomes light.
When the setting of TR-TP-LV is not 0, the setting of TR-TP-TM becomes effective.
-50 to 50
%
0
COPIER> ADJUST> HV-TR> TR-TP-TM
0.01
For R&D
1.0444
For R&D
1.0444
For R&D
1.0444
For R&D
1.33
For R&D
1.33
For R&D
1.0444
For R&D
1.0444
For R&D
1.33
For R&D
1.33