Canon imageRUNNER ADVANCE 4551i Service Manual page 778

Hide thumbs Also See for imageRUNNER ADVANCE 4551i:
Table of Contents

Advertisement

COPIER > OPTION > CUSTOM
FLK-RD
2
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Default Value
TMP-TBL
2
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Default Value
DFEJCLED
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Default Value
RDEV-SP1
2
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Default Value
RDEV-SP2
2
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Default Value
RDEV-SP3
2
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Default Value
Flicker reduction mode
To change the fixing temperature control to cancel fluorescent flicking during printing
When the fluorescent flicking occurs during printing
Enter the setting value, and then press OK key.
0 to 1
0: OFF, 1: ON
0
Shortening FCOT
To lower the fixing control temperature for paper pickup by 40 degree centigrade against the fixing
control temperature at the first copying.
This setting is effective when the fixing mode is the thin paper 1/2 and plain paper 1/2 and OHP.
To shorten the first copy time, the fixing control temperature for the paper feed start is lowered (-40
deg C).
Enter the setting value, and then press OK key.
0 to 1
0: OFF, 1: ON
0
ON/OFF of DADF delivery LED
To set whether to light up the delivery LED of DADF.
Upon user's request (The LED is too bright)
Enter the setting value, and then press OK key.
0 to 1
0: ON, 1: OFF
0
RCON device special settings 1
To execute the device special setting.
For customization
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Use this mode only when specific instructions are given.
00000000 to 11111111
0
RCON device special settings 2
To execute the device special setting.
For customization
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Use this mode only when specific instructions are given.
00000000 to 11111111
0
RCON device special settings 3
To execute the device special setting.
For customization
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Use this mode only when specific instructions are given.
00000000 to 11111111
0