Canon imageRUNNER ADVANCE 4551i Service Manual page 478

Hide thumbs Also See for imageRUNNER ADVANCE 4551i:
Table of Contents

Advertisement

719-0001-00
Detection Description
Remedy
719-0002-00
Detection Description
Remedy
719-0003-00
Detection Description
Remedy
719-0004-00
Detection Description
Remedy
719-0031-00
Detection Description
Remedy
719-0032-00
Detection Description
Remedy
720-0001-00
Detection Description
Remedy
Error in Coin Vendor.
Error in starting of the CoinVendor
- The Coin Vendor, which should have been connected before the power was turned OFF, is not
connected when the power is turned ON.
Check the connection between charging management equipment and machine, and check that
the Cable is not open-circuit.
Clear the error while the charging management equipment is connected to operate and when
switching to the operation without charging management equipment.
(To prevent the misuse by removing the charging management equipment, this error code is
displayed.)
Error in Coin Vendor.
Error in IPC when CoinVendor is running.
- In the case of disconnection of IPC or an error in which IPC communication failed to be recovered.
- When disconnection of the pickup delivery signal is detected.
- When illegal connection is detected (short-circuit with Tx and Rx of IPC)
Check the connection between charging management equipment and machine, and check that
the Cable is not open-circuit.
Clear the error while the charging management equipment is connected to operate and when
switching to the operation without charging management equipment.
(To prevent the misuse by removing the charging management equipment, this error code is
displayed.)
Error in Coin Vendor.
- In the case of communication error with the coin vendor while obtaining the unit price at start-up.
Check the connection between charging management equipment and machine, and check that
the Cable is not open-circuit.
Clear the error while the charging management equipment is connected to operate and when
switching to the operation without charging management equipment.
(To prevent the misuse by removing the charging management equipment, this error code is
displayed.)
Coin vendor error
The coin vendor was connected to a model that does not support the coin vendor
1. Disconnect the coin vendor
Error in serial communication at the start of the New Card Reader
Failure in communication with the serial New Card Reader at start-up.
- Check if the cable of the serial New Card Reader is disconnected.
- Take out the serial New Card Reader.
- COPIER > Function > CLEAR > CARD
- COPIER > Function > CLEAR > ERR
Error in serial communication at the start of the New Card Reader
Communication failed in the middle of the operation although communication with the serial New
Card Reader was successful at start-up.
- Check if the cable of the serial New Card Reader is disconnected.
Error due to non-compatible Finisher
Non-compatible Finisher was connected.
Connect either the Staple Finisher-Y1 or Saddle Stitch Finisher-Y1.
465
7. Error/Jam/Alarm

Advertisement

Table of Contents
loading

Table of Contents