Canon imageRUNNER ADVANCE 4551i Service Manual page 741

Hide thumbs Also See for imageRUNNER ADVANCE 4551i:
Table of Contents

Advertisement

COPIER > OPTION > FNC-SW
VER-CHNG
2
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Default Value
Supplement/Memo
B4-USE
2
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Default Value
CE-SW
1
PICLOGIN
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Default Value
Additional Functions
Mode
Setting of firmware update operation
To set how to update firmware of PCB/option which has been installed/replaced by comparing the
version of it with the version stored in the Flash PCB of the Main Controller.
If combination of firmware versions of PCB/option stored in the Main Controller and the version in
PCB/option after installation/replacement is not appropriate (operation with the combination of
firmware versions has not yet been checked), failure where analysis is difficult may occur.
It is possible to check the firmware versions at the start of the machine, and automatically write
the firmware stored in the Main Controller in PCB/option collectively as needed.
When 0 is set, versions are not checked and firmware update is not performed. Therefore, it is
necessary to manually update the versions using a USB memory/SST.
When 1 is set, firmware is updated if the version in PCB/option is old. However, it is not updated
if the version is new or old and new versions are mixed.
When 2 is set, a compatible firmware (the version where operation has been checked) is written
from the Main Controller regardless of whether the version in PCB/option is old or new.
When installing/replacing PCB/option having firmware
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
0 to 2
0: Keep the current firmware version.
1: Update the firmware if the version in PCB/option is older than that stored in the Main controller.
If the version is new or old and new versions are mixed, firmware is not updated.
2: Update the firmware regardless of whether the version is old or new if the version in PCB/option
differs from that stored in the Main Controller.
1
When updating the firmware, the main menu is displayed on the Control Panel at startup and then
a message prompting to update firmware is displayed.
By pressing [Update], the machine reboots immediately and firmware is updated.
By pressing [Skip], it returns to the main menu. The message is displayed again at next startup.
ON/OFF of B4 size detection
To set whether to detect B4 size paper with Inch configuration machine.
If the Trailing Edge Guide Plate is not set properly when LTR size paper is set in a cassette, the
machine may recognize the paper size as B4. Since B4 size paper is rarely used with Inch
configuration machine, it is set not to detect B4 size paper.
When 0 is set, a pop-up message prompting to set the Trailing Edge Guide Plate properly is
displayed if the machine recognizes paper size as B4.
When 1 is set, B4 size can be detected.
The setting is applied to all cassettes except the Multi-purpose Tray.
When using B4 size paper with Inch configuration machine
Enter the setting value, and then press OK key.
The setting is enabled only with Inch configuration machine.
0 to 1
0: OFF, 1: ON
0
[Reserve]
ON/OFF of Picture Login display
To set whether to display "Picture Login" in Settings/Registration menu.
When switching the Picture Login function
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
0 to 1
0: OFF, 1: ON
1
Management Settings> User Management> Authentication Management> Use User
Authentication> Picture Login
728
8. Service Mode

Advertisement

Table of Contents
loading

Table of Contents