■ ENV-SET
COPIER > OPTION > ENV-SET
ENVP-INT
1
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Unit
Default Value
Related Service Mode
Additional Functions
Mode
Amount of Change per
Unit
DRY-CISU
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Default Value
IMG-BLD1
2
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Default Value
Related Service Mode
Additional Functions
Mode
Supplement/Memo
Temp&hmdy/Fix Film temp log get cycle
To set the cycle to obtain log of the temperature and humidity inside the machine and the surface
temperature of the Fixing Film.
As the value is incremented by 1, the cycle is increased by 1 minute.
Collected log can be displayed in COPIER> DISPLAY> ENVRNT.
At trouble analysis
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Be sure to set "High" for [Sleep Mode Energy Use] in [Settings/Registration] before collecting logs,
and change the value back to its original setting after log collection.
0 to 480
min
60
COPIER> DISPLAY> ENVRNT
Preferences> Timer/Energy Settings> Sleep Mode Energy Use
1
Set condensation prev mode (Single pass)
To set ON/OFF of condensation prevention mode.
In the Single pass DADF model, set 1 when an image failure or E302 occurs due to condensation
in the scanner unit.
When setting 1, from the next startup, the LED of the scanner unit for back side lights for 30 seconds
after the end of the job.
When droplets appear on the Scanner Unit due to condensation and image failure or E302 occurs
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
0 to 1
0: OFF (Normal mode), 1: ON (Condensation prevention mode)
0
Set image smear prevention mode
To warm around the Developing Assembly and the Photosensitive Drum with the following
operation to prevent image smear.
When either 1, 2 or 3 is set, "Clean Drum" is displayed in user mode, and user can execute only
setting 2.
When the value is increased, the effect becomes big.
When image smear occurs
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
0 to 3
0: OFF
1: Two minutes extension in the initial rotation
2: Four minutes extension in the initial rotation
3: Six minutes extension in the initial rotation
0
COPIER> OPTION> ENV-SET> IMG-BLD4
Settings/Registration> Adjustment/Maintenance> Clean Drum> Start
When this mode and the low temperature fogging prevention mode (IMG-BLD4) have been set
together, this mode becomes effective preferentially.
748