Canon imageRUNNER ADVANCE 4551i Service Manual page 399

Hide thumbs Also See for imageRUNNER ADVANCE 4551i:
Table of Contents

Advertisement

009-0000-05
Detection Description
Remedy
009-0001-05
Detection Description
Remedy
010-0001-05
Detection Description
Remedy
Fixing Unit pressurization error
The pressurization of the Fixing Pressure Release Sensor (S53) was not detected for 1.5 seconds
during the Fixing Motor(M2) pressurization drive.
[Related parts]
- Harness connecting from the DC Controller PCB (UN2/J307) to the Fixing Pressure Release
Sensor (S53/J710)
- Fixing Pressure Release Sensor (S53)
- DC Controller PCB (UN2)
[Remedy]
1.Check/replace the harness and connector between the DC Controller PCB and the Fixing Main
Thermistor.
2.Replace the DC Controller PCB.
[Reference]
Before replacing the DC Controller PCB, back up the service mode data and restore the backup
data after the replacement so the data may be able to be protected.
- Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP
- Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Fixing Unit pressure release error
The pressure release of the Fixing Pressure Release Sensor (S53) was not detected for 1.5
seconds during the Fixing Motor(M2) pressure release drive.
[Related parts]
- Harness connecting from the DC Controller PCB (UN2/J307) to the Fixing Pressure Release
Sensor (S53/J710)
- Fixing Pressure Release Sensor (S53)
- DC Controller PCB (UN2)
[Remedy]
1.Check/replace the harness and connector between the DC Controller PCB and the Fixing Main
Thermistor.
2.Replace the DC Controller PCB.
[Reference]
Before replacing the DC Controller PCB, back up the service mode data and restore the backup
data after the replacement so the data may be able to be protected.
- Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP
- Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Unstable rotation of the Main Motor (M1)
Detection is executed every 100 msec after the start of motor rotation; however, the drive detection
signal is absent for 2 sec.
[Related parts]
- Harness connecting from the DC Controller PCB (UN2/J309) to the Main Motor (M1/J137)
- Main Motor (M1)
- DC Controller PCB (UN2)
[Remedy]
1.Check/replace the related harness/cable, connector and parts.
2.Replace the DC Controller PCB.
[Reference]
Before replacing the DC Controller PCB, back up the service mode data and restore the backup
data after the replacement so the data may be able to be protected.
- Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP
- Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES