Replace the UV Filter

Wear clean, lint-free gloves, and handle the UV filter by its edges.
The UV filter is secured to the end of the light tube. If a lamp explodes, the UV filter must be
replaced.
1. Turn the lamp off and cool the projector for at least 15 minutes.
2. Turn the projector off and then disconnect it from AC power.
3. Remove the top lid. See
4. Remove the lamp. See
5. Remove the reflector assembly. See
6. Remove the top 2 screws and the attached clamps from the UV filter housing.
7. Slowly loosen the bottom screw until you can remove the UV filter.
8. To reinstall the UV filter, perform the steps in reverse order. Make sure that the filter is installed
with the arrow indicator on the edge of the filter pointing towards the lamp.
CP2215 Service Manual
020-101226-03 Rev. 1 (10-2015)
Remove the Top Lid
Remove the Existing Lamp
Remove the Reflector Assembly
Top screws
A
Bottom screw
B
Parts and Module Replacement
on page 22.
on page 28.
on page 34.
35