8.4.3 Setting Procedures and Operations (Ratio Specification Method)

 Setting procedures and operations of ratio specification method (Override)
When setting the ratio specification, the command speed is immediately reflected in the
specified ratio once the "Ratio specification" in the unit memory is changed.
f
200,000pps
100,000pps
50,000pps
100(%)
Operation speed rate
(Note 1): The acceleration time to the change speed and the deceleration time from the change speed follow the
setting values of the active table.
(Note 2): The movement amount does not change when the speed change is performed.
 Setting parameters of ratio specification method
The following parameters are used in the target speed change function of the ratio
specification method.
Positioning operation change setting area
Unit
Axis no.
memory
no. (Hex)
Axis 1
UM 00380
Axis 2
UM 00381
:
:
Virtual
UM 003C0
axis 1
:
:
Virtual
UM 003DF
axis 32
200(%)
50(%)
Name
Default
Operation
U100
speed rate
8.4 Target Speed Change Function
100(%)
Description
All operations relating to axes (positioning, JOG
operation, home return) can be performed at the
specified rate.
Range: 0 to 500 (%) (For single axis control)
0 to 200 (%) (For interpolation control)
t
8-33