Execution order of synchronous control and setting procedures
The following section provides information on the outline of functions achieved by
synchronous control and setting procedures for the functions.
Master axis operation
Slave axis output
Make master axis settings for each operating axis.
Master axis
settings
Each operating axis will work as a slave axis if master axis settings
are made for the operating axis.
Select the use or non-use of the electronic gear. Various electronic
Electronic gear
settings
gear settings are required if the electronic gear is used.
Phase clutch OFF
Select the use or non-use of the electronic clutch. Various
Electronic clutch
settings
electronic cutch settings are required if the electronic gear is used.
Advance angle
correction
Select the use or non-use of the electronic cam. Various electronic
Electronic cam
settings
cam settings are required if the electronic gear is used.
In addition, electronic cam pattern settings are required in the case
of using the electronic cam.
9.1 Synchronous Control
9-3