Automatic Operation (Synchronous Control)
Cam pattern setting
Press the "Insert" button from the "Section" field. Set the start phase, and press the [OK]
button. In the default condition, only one section whose phase is 0 to 100% can be set for the
cam pattern. By setting the start phase, the above section is divided into multiple sections.
The background of the selected sections is displayed in white, and the background of the
unselected sections is displayed in gray.
The start phase may not be a specified phase value due to the relation with resolution.
9-32