If the control is accessed via LSV2 protocol, the IP address of the external unit is entered in
Entry of IP
addition to the entry REMO A_LG.
addresses
Figure: Entry of IP address of accessing unit (laptop/PC) in the log
The IP address is shown in hexadecimal notation and can be converted to decimal notation as
follows:
The first two HEX digits from the left represent the first 3-digit decimal number of the IP address;
the next two HEX digits from the left represent the second 3-digit decimal number of the IP
address, etc.
Example for the IP address 0xA001F3B8:
Transformation IP address
Hexadecimal display
B8
F3
01
A0
Result IP address
Hexadecimal display
0xA001F3B8
Operating-system error messages require a rebooting of the control. During rebooting the
Entry of operating
operating-system error message is entered in the log. The time when the operating-system error
system error
message is entered in the log is indicated, i.e., the reboot time. In the headline of the operating-
messages
system error message the Greenwich Mean Time (Universal Time) is shown.
July 2010
Decimal display
184
243
1
160
Decimal display
160.1.243.184
8 – 85