MP
Function and input
MP6170
Number of measurements in a programmed measurement (touch probe block)
Input:
MP6171
Confidence range for programmed measurement
(MP6170 > 1)
Input:
MP6180
Coordinates of the ring gauge center for automatic calibration (Probing Cycle 2) with
respect to the machine datum (traverse range 1)
Input:
MP6180.0
X coordinate
MP6180.1
Y coordinate
MP6180.2
Z coordinate
MP6181
Coordinates of the ring gauge center for automatic calibration (Probing Cycle 2) with
respect to the machine datum (traverse range 2)
Input:
MP6181.0
X coordinate
MP6181.1
Y coordinate
MP6181.2
Z coordinate
MP6182
Coordinate of the ring gauge center for Probing Cycle 2 with respect to the machine
datum (traverse range 3)
Input:
MP6182.0
X coordinate
MP6182.1
Y coordinate
MP6182.2
Z coordinate
MP6185
Distance of probing point below ring top surface during calibration
Input:
30 – 612
1 to 3
0.002 to 0.999 [mm]
0.0000 to 99 999.9999 [mm]
0.0000 to +99 999.9999 [mm]
0.0000 to +99 999.9999 [mm]
+0.001 to +99 999.9999 [mm]