Principally, all functions of Windows can be used with the dual-processor control. Windows also
With the dual-
includes hard-disk test programs.
processor control
(with Windows)
You can use the following test routine:
July 2010
Note
To perform this hard disk test Windows must boot completely (not always possible when
the hard disk is defective)!
Furthermore, you require certain local administrator rights in Windows. --> Ask the machine
manufacturer!
Caution
First close all programs in Windows before you activate the test programs. This also
applies to the iTNC application!
Changes in Windows may influence the function of the control!
HEIDENHAIN cannot guarantee the function of Windows applications!
If possible: Move the machine to its basic position.
Press the WINDOWS key.
Close all programs in Windows.
Exit the iTNC application as follows:
Double-click the HEIDENHAIN symbol in the task bar.
--> The iTNC Control Panel is opened.
Now click on Shut Down.
The following window appears:
Press the EMERGENCY STOP key and click Yes.