Bits 7 and 8 of MP2195 enable you to deactivate the error messages that may be triggered by
the evaluation of these signals (PF.PS.AC, PF.PS.DC), without changing the SUPPLY.SPY table.
MP2195
Input:
July 2010
Note
Signals that change their status during operation are always identified as errors.
Only as of CC424 (B): Errors of the supply module (e.g. excessive Uz temp.) lead to an NC
stop (if M148 then LIFTOFF) with a subsequent emergency stop.
Handling of status signals from HEIDENHAIN power supply units
Bit 0 - status signals that are already active during control power-up
0: Missing signals are ignored
1: Missing signals are evaluated
Bit 1 - ERR.UZ.GR signal
0: Error message is not suppressed
1: Error message is suppressed
Bit 2 - ERR.TMP signal
0: Error message is not suppressed
1: Error message is suppressed
Bit 3 - reserved
Bit 4 - ERR.IZ.GR signal
0: Error message is not suppressed
1: Error message is suppressed
Bit 5 - RDY.PS signal
0: Error message is not suppressed
1: Error message is suppressed
Bit 6 - ERR.ILEAK signal
0: Error message is not suppressed
1: Error message is suppressed
Bit 7 - PF.PS.AC
0: Previous behavior; Error message is not suppressed
1: Error message is suppressed
Bit 8 - PF.PS.DC
0: Previous behavior; Error message is not suppressed
1: Error message is suppressed