HEIDENHAIN iTNC 530 Service Manual page 190

Hide thumbs Also See for iTNC 530:
Table of Contents

Advertisement

In the upper half of the screen (laptop/PC contents), select the target drive and the target
Reading out data
using TNCremoNT
directory:
In the lower screen half (iTNC 530 contents), select the source drive and the source directory:
Figure: Changing to the PLC partition
Transfer the data:
13 – 190
Click the bar with the drive information. --> Its color changes from gray to blue, and two
buttons appear at the right side in the bar.
Click the Change folder/drive... button. --> A new window opens.
Now, select the drive and the folder. --> The path is displayed in the blue bar.
Note
For the data zu be read out, you can create a folder on your laptop with TNCremoNT. For this
purpose, click the icon Create folder or select File / Create folder ... from the menu.
Click the bar with the drive information. --> Its color changes from gray to blue, and two
buttons appear at the right side in the bar.
Click the Change folder/drive... button. --> A new window opens.
Now, select the drive and the folder. --> The path is displayed in the blue bar.
Note
For changing to the PLC: und SYS: control partitions, the respective code numbers are
interrogated.
Using the mouse, click the directory you wish to read out.
Press and hold the left mouse button and pull the directory or the file into the upper window.
Release the mouse button. --> The file is being transferred.
HEIDENHAIN Service Manual iTNC 530