HEIDENHAIN iTNC 530 Service Manual page 420

Hide thumbs Also See for iTNC 530:
Table of Contents

Advertisement

Functional test
By means of DriveDiag:
25 – 420
DANGER
Consult the machine operator and observe the machine manufacturers's safety precautions
(setup mode, etc.)!
Switch on the machine.
Insert the touch probe.
As a precaution press the EMERGENCY STOP button.
Call the DriveDiag. --> See "Integrated Diagnostic Functions and DriveDiag" on page 9 – 89.
Open the following page:
Check the lamp at TS touch probe ready (X12).
When the touch probe is ready, the lamp shines green.
Deflect the stylus by hand.
Check the lamp at Trigger signal (X12) of TS touch probe.
When the stylus is deflected, the lamp shines green.
You can also check the lamp at Battery (X12) of TS touch probe.
If the battery capacity is sufficient, this lamp shines green.
With touch probe systems with cable, this lamp shines red.
HEIDENHAIN Service Manual iTNC 530

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents