Figure: Check mark with READ_MP.A has been removed
If the control opens the machine parameter list after you have restored the back up, new
Updating the
machine parameters are added with the current NC software of the replacement hard disk or
machine
older MPs are removed.
parameter list
The following messages may be generated:
28 – 540
Press the END key.
Enter a value for the new machine parameter.
Note
Comments on the new MPs can be found in the text file READ_MP.A or READ_MP.A in path
PLC:\JH\ ...
Contact the machine manufacturer for more information!
If required you can add comments on the function of the new parameters in the MP list.
The parameter is not required. --> Delete this MP or mark the parameter as comment so it
remains in the machine parameter list.
After each change, try to activate the machine parameter list with END.
If the MP list is complete, the iTNC 530 restarts.