Flowchart for
individual axis
July 2010
Position capture with motor encoder
(indirect measurement) with an individual axis
The machine is switched off.
Press the EMERGENCY-STOP button and turn the
feed rate potentiometer to zero.
Switch on the main switch of the machine.
Do not confirm the Power interrupted message
but immediately call the MP list.
Deactivate the position encoder for the axis concerned.
Enter the value 0 for the axis concerned in MP 110.x
(assignment of the position encoder inputs).
Deselect the reference run for the axis concerned by
entering the value 0 in MP 1340.x (sequence when
traversing the reference marks).
Enter the value of MP 1054.x (distance of one motor
revolution) in MP 331.x (distance for the number of
signal periods of MP 332).
Enter the line count of the motor encoder (information from,
e.g., the motor table) in MP 332.x (number of the signal
periods for the distance in MP 331).
Exit the MP list and switch on the machine.
Travers the axis carefully!
Display of error messages, such
as Incorrect entry in MP 1040.x or
movement monitoring, standstill
monitoring, etc.?
Now you can traverse carefully with indirect measurement!
Yes
No
Press the EMERGENCY-
STOP button and invert
either MP 1040.x (algebraic
sign of the nominal speed
value) or MP 210.x
(counting direction of the
position encoder signals).