Compatibility of
HEIDENHAIN
interface boards
and SIMODRIVE
power modules
July 2010
SIEMENS has revised the SIMODRIVE power modules.
Among other things the interference suppression circuits have been supplemented.
In 2007, the HEIDENHAIN interface boards suitable for the modified SIMODRIVE power
modules were also improved:
Modified SIMODRIVE
power modules
At the end of the
SIEMENS ordering
designation of the
improved power modules
you find the
code A2 or A3
The HEIDENHAIN interface boards listed in the above table replace the previous variants.
This means that they may also be inserted in "older" SIMODRIVE power modules.
Caution
"Older" HEIDENHAIN interface boards may not be operated with modified SIMODRIVE
power modules.
Possible errors and error messages --> See "Overview of Possible Error Patterns" on page
5 – 55.
Matching HEIDENHAIN
interface boards
324952-03, index A
324952-12, index D
324955-17
359002-05
515012-03
Description
2-axis version, D-sub
connector
2-axis version, D-sub
connector
1-axis version, ribbon-
cable connector
2-axis version, ribbon-
cable connector
1-axis version, ribbon-
cable connector