19.5 Corrective Action

19.6 Deselecting the Reference Run for Axes

For axis examinations it is possible to deselect the referencing in MP 1340.x .
19 – 320
Repair the trip dogs.
Replace the encoder, See "Encoder Interface" on page 18 – 277.
Readjust shifted magnet or replace damaged magnet. Do not forget spacer plates (filler
pieces)!
Readjust shifted ref. mark selector plate.
Use a special slider. --> Ask a HEIDENHAIN service agency!
Have the removed or damaged enamel repainted. --> Ask a HEIDENHAIN service agency!
Adjust the trip dogs relative to the motor encoder ref. pulse. --> See "Readjusting the trip dog
for reference end position" on page 18 – 305.
Enter value 0 (= no evaluation of the reference mark) for the corresponding axis or for all axes.
Note
In MP1340.x the sequence for the reference mark run is listed.
With following entries, i.e.:
MP1340.0 : 3
MP1340.1 : 2
MP1340.2 : 1
... first the 3rd axis is referenced (e.g., Z axis), then the 2nd axis (e.g., Y axis) and
subsequently the 1st axis (e.g., X axis).
If you now want to deselect the X axis, you must enter MP1340.2 = 0!
However, the reference run is normally deselected for all axes.