HEIDENHAIN iTNC 530 Service Manual page 211

Hide thumbs Also See for iTNC 530:
Table of Contents

Advertisement

July 2010
Confirm your selection with the YES soft key.
Note
If now the error message Not enough space on SYS: is generated, packed NC software
versions must be deleted from the SYS partition. This is done in the mentioned selection
window with the DELETE soft key.
Ask the machine manufacturer which NC software versions may be deleted!
The control activates the selected NC software again and performs a reset.
Call again the machine parameter list.
Press the MOD key.
Press the UPDATE DATA soft key.
Press the ASC --> BIN soft key to convert the files on the hard disk from ASCII to binary
format.
If a service pack was active on the machine (what you have noted down), you must now load
it. --> See "Loading of Service Packs" on page 15 – 219 .
Check the NC software version incl. related Service Pack. --> Press the MOD key.
Finally, check the machine functions!
14 – 211