From the PLC main menu you can use soft keys to access the following PLC functions:
PLC functions of the
main menu
July 2010
Soft key Function
Edit the file located in RAM memory.
Call the diagnostic functions.
Compile files registered in OEM.SYS.
Select and compile files to be compiled.
Stop and restart the PLC program (M4173
is supported).
Show a list of machine parameters.
Set inputs and outputs. The PLC program is
ignored.
Display states of selected operands in
tabular format.
Display the logical states of the PLC
operands.
Show the logic diagram.
Display the TRACE function.
Display the process monitor.
Activate the integrated oscilloscope.
End PLC programming.
Description in this manual
See "Integrated Diagnostic Functions
and DriveDiag" on page 9 – 89.
See "The Machine Parameter Editor"
on page 30 – 572.
See "The I / O - FORCE LIST" on page
11 – 131.
See "The WATCH LIST function" on
page 11 – 129.
See "The TABLE function" on page 11
– 119.
See "The LOGIC diagram" on page 11
– 125.
See "The TRACE function" on page
11 – 128.
See "Integrated Oscilloscope" on
page 10 – 99.