Overview of
operands
Operand
Abbreviation
Markers
M (marker)
Input
I (input)
Output
O (output)
Counter
C (counter)
Timer
T (timer)
Byte
B (byte)
Word
W (word)
Double word
D (double word)
Constant
K
String
S
11 – 146
Address range
M0 to M9999
M0 to M999 free; are deleted only after entry of the code number 531210, not
by a reset (non-volatile range). The range can be reduced or enlarged in the
*.CFG file of the PLC compiler.
M1000 to M3999 are free; they are deleted during reset.
M4000 to M5999 reserved for NC/PLC interface
(M4800 to M4999 are deleted before the first run of the PLC program, e.g. after
compilation or restarting).
M6000 to M9999 are free. They are deleted during reset.
I0 to I31
I128 to I152
I160 to I175
I64 to I127
I192 to I255
I256 to I319
I320 to I383
O0 to O30
O0 to O7
O96 to O111
O32 to O62
O64 to O94
O128 to O158
O160 to O190
C0 to C47
C48 to C95
C96 to C143
T0 to T47
T48 to T95 and T96 to T999
B0 to B9999 (8 bits)
B0 to B255 are free; depending on the definition in the *.CFG file of the PLC
compiler, the defined range is deleted only after entering the code number
531210, not during reset (nonvolatile range). If no range is defined in the *.CFG
file, B0 to B127 is the nonvolatile range.
B256 to B2047 reserved for NC/PLC interface.
B2048 to B9999 are free; they are deleted during reset.
–2 147 483 647 to +2 147 483 647
S0 to S99
Note
1 byte = 8 bits
1 word = 2 bytes = 16 bits
1 double word = 2 words = 4 bytes = 32 bits
(MC)
(Machine operating panel)
(HR 410, HRA 110)
(first PL)
(second PL)
(third PL)
(fourth PL)
(MC)
(via machine operating panel)
(HR 410, HRA 110)
(first PL)
(second PL)
(third PL)
(fourth PL)
Set the counter
Counter content
Counter pulse release
Timer start
Timer is running
HEIDENHAIN Service Manual iTNC 530