HEIDENHAIN iTNC 530 Service Manual page 591

Hide thumbs Also See for iTNC 530:
Table of Contents

Advertisement

MP
Function and input
MP1350.x
Sequence for finding the reference mark
Input:
1: Position encoder with one reference mark
2: Special type (length measurement with ROD)
3: Linear encoder with distance-coded reference marks (new routine)
4: Same as 3 except that two reference marks are evaluated
5: Encoder with EnDat interface
6: Reference pulse via fast PLC input
MP1352
Activate the software limit switches before traversing the reference marks
Format:
Input:
0: Software limit switch not active
1: Software limit switch active
MP1355
Double reference run
Format:
Input:
0: Reference run as defined in MP1350.x
1: Double reference run
MP1356.x
Distance between speed and position encoder for double reference run.
Input:
MP1357.x
W1032 for double reference run
Input:
speed encoder
1: Reset W1032 if the reference mark was traversed with the position encoder
MP1360.x
Fast PLC input for reference pulse
Input:
1 to 5: Fast PLC input 1 to 5 (MP4130.x)
MP1391
Velocity and acceleration feedforward control in the MANUAL and HANDWHEEL
operating modes
Format:
MP1391.0
Velocity feedforward control
Input:
0: Inactive
1: Active
MP1391.1
Acceleration feedforward
Input:
0: Inactive
1: Active
MP1392
Velocity feedforward in the POSITIONING WITH MANUAL DATA INPUT, PROGRAM
RUN SINGLE BLOCK and PROGRAM RUN FULL SEQUENCE operating modes
Format:
Input:
0: Operation with following error (lag)
1: Operation with velocity feedforward control
MP1396.x
Feedback control with velocity semifeedforward
Input:
1: Velocity feedforward control
July 2010
0: Linear encoder with distance-coded reference marks (old routine)
%xxxxxxxxxxxxxx
Bits 0 to 13 represent axes 1 to 14
%xxxxxxxxxxxxxx
Bits 0 to 13 represent axes 1 to 14
-99 999.999 to +99 999.999 [mm] or [°]
0: Reset W1032 if the reference run has been over the EnDat interface of the
0: No fast PLC input for reference pulse
%xxxxxxxxxxxxxx
Bits 0 to 13 represent axes 1 to 14
Bits 0 to 13 represent axes 1 to 14
%xxxxxxxxxxxxxx
Bits 0 to 13 represent axes 1 to 14
0.001 to 0.999
SW version
and
behavior
PLC
RUN
REF
340 490-04
340 420-05
PLC
RUN
REF
340 420-05
PLC
RUN
REF
340 422-05,
340 480-05
PLC
RUN
PLC
RUN
REF
340 490-01
PLC
RUN
PLC
RUN
PLC
RUN
30 – 591