Example of a circular interpolation test with the integrated oscilloscope:
Actual position:
X +30
Y +0
0 BEGIN PGM Circular interpolation test MM
1 CC X+0 Y+0
2 CP IPA+5000 DR+ F1000
3 M30
4 END PGM Circular interpolation test MM
10.5.3 Descriptions in this manual
The use of the integrated oscilloscope for error diagnosis is described in the respective
chapters of this Service Manual.
10 – 114
Note
Ask the machine operator how to operate the machine and how to create and execute the
NC program!
Position the axes in an area that allows safe traverse of the circle.
Set the reference points for X and Y as follows:
Write a simple NC program, such as:
Start this NC program in the automatic mode and start oscilloscope
recording.
Stop recording and adjust the display.
Note
You can run the circular interpolation test at different positions, at different speeds and with
different radii!
HEIDENHAIN Service Manual iTNC 530