13.2 Connection Setup

13.2.1 Via Ethernet

Requirements
On the single-processor control, the Ethernet interface is managed by the HEIDENHAIN
Management of the
operating system HeROS. The settings of the Ethernet interface can be interrogated via the
Ethernet interface
on the iTNC 530
code number NET123.
With the dual-processor control, the Ethernet interface is managed by Windows. The settings of
the Ethernet interface can, for example, be interrogated with the command ipconfig in the
prompt.
Ask your system administrator!
Connection via your
local network
It is advisable to set up a direct connection between your service laptop and the control (peer-
Connection
to-peer).
establishment at
the customer's
(field service)
Figure: Example for peer-to-peer connection
13 – 172
A laptop/PC with an Ethernet card
Either an Ethernet crossover cable for direct connection of laptop and control ("peer-to-peer
connection") or a non-crossed Ethernet cable (patch cable) for connection via your local
network (intranet).
Note
Mark your cable as "crossed" or "non-crossed"!
Note
On modern laptops the Ethernet interface is set automatically.
Here, it is of no importance, whether the connected Ethernet cable is crossed or non-
crossed.
Ask your customer whether you may disconnect the control from his in-house network for the
duration of your work.
Connect your laptop directly to the control by means of a crossed Ethernet cable.
CC / MC
Control
X127
X128
IP address
160.1.178.12
Subnet mask
255.255.0.0
Crossed
Ethernet cable
IP address
Subnet mask
HEIDENHAIN Service Manual iTNC 530
Laptop
160.1.178.13
255.255.0.0